Performance characteristics

 

 

 

Batch size lbs {g}

0.882 {400}

0.882 {400}

0.882 {400}

Maximum throughput lbs/hr {kg/hr}*

97 {44}

111 {50}

132 {60}

Bin capacity - standard bins ft3 {liter}

0.4 {5.7}

0.4 {5.7}

0.4 {5.7}

Maximum number of materials

4

4

4

Number of standard dispensing valves

2

3

4

Number of micro dispensing valves

2

1

0

Control software (# of components)

4 or 12

4 or 12

4 or 12

Dimensions inches {mm}

 

 

 

A - Height above mounting plate

27.25 {693}

27.25 {693}

27.25 {693}

B - Width

21.75 {552.4}

21.75 {552.4}

21.75 {552.4}

C - Depth

21.75 {552.4}

21.75 {552.4}

21.75 {552.4}

D - Controller height

11.25 {285.75}

11.25 {285.75}

11.25 {285.75}

E - Controller width

12.25 {311.15}

12.25 {311.15}

12.25 {311.15}

F - Controller depth

8.19 {208.03}

8.19 {208.03}

8.19 {208.03}

Weight lbs {kg}

 

 

 

Installed

60 {27}

60 {27}

60 {27}

Shipping

80 {36.3}

80 {36.3}

80 {36.3}

Voltage Running load amps

 

 

 

120V/1 phase 50/60 hz

1.0

1.0

1.0

220V/1 phase 50/60 hz

0.5

0.5

0.5

Compressed air requirements

 

 

 

 

40 psi @ 1 ft3/min { bars @ 0.47 liters/sec}

 

 

1/4 in. NPT fitting

 

Material filling options

 

 

 

Self-contained vacuum loader

 

ML8

 

Central vacuum receiver

 

DL8

 

Hand-fill

 

flat lid

 

 

 

 

 

MOUNTING INTERFACE

SPECIFICATION NOTES:

*Maximum throughput rates are based on using all dispense valves dispensing no more than 1.0% colorant or additive per each micropulsing valve. Refer to the selection guide for more specific throughput informa- tion.

APPLICATION NOTE:

Handfill unless otherwise specified.

If you will be using this blender for central blending applications, it will be necessary to use a flow control valve with an air solenoid.