Conair WSB EXIT will exit the sequence and close all outputs, Timed, Press, once, followed by one

Models: GB WSB

1 119
Download 119 pages 6.25 Kb
Page 34
Image 34

any other 5 digit number, if you wish, as explained later (*45). When in the MANUAL mode, the letter "M" shows at the left end of display.

The following manual functions are available in the MANUAL mode.

OPERATE: Press once followed by one of 16 keys: 1 through 9, A, B,

(OPER) C, DUMP, ALRM, MIX, or HOLD. The selected output operates until the key is pressed again or another output is selected. Only 1 output will be active at a time.

EXIT will exit the sequence and close all outputs.

TIMED:

Press

once

followed by one

of

12 component

keys.

A time in

(TIME)

interrupts

is requested; (TIME

---).

Three digits must

be

 

entered specifying

a dispense

time up

to 999 interrupts

 

 

(about 4

seconds maximum.)

CE

will

cancel

entry before

last

 

digit

is

entered.

Following a

full

3

digit time

entry,

the

specified output is activated for the time requested. After the dispense is weighed, the dump valve automatically operates to empty the weigh bin. If a printer is on line and the Print flag is ON, then output information will be printed. EXIT will exit the sequence.

CALIBRATE: (RATE) Press once followed by one of the 12 component keys.

(CAL) A dispense will occur for 2 seconds. If the amount dispensed is less then 50 grams, a second dispense will occur for 20 seconds. Using the resulting weight and time, the processor calculates a proper beginning point dump rate for the start of production blending. After each dispense is weighed, the weigh bin dump valve automatically operates to empty the weigh bin. If a printer is on line and the Print flag is ON (see KEYPAD *54), then output information will be printed. EXIT will exit the sequence.

If the display says (DO AGAIN), press any key to cause the process to repeat itself. If the display then says

( NO GOOD), the dispense weight was below 2 grams, not enough for a valid calibration.

During initial operation, after each power up, the blender calibrates itself completely automatically, regardless of how far off the initial flow rate may be. This may take several cycles. During normal operation, calibration correction occurs continuously.

Since this unit adjusts flow rates automatically, manual Rate Calibration is not necessary for proper operation.

ZERO WT.

THIS HAS BEEN DONE AT THE

FACTORY. IT SHOULD NOT

BE

(ZERO)

NECESSARY FOR YOU TO DO THIS AGAIN.

 

 

For this key to function,

you must first set the

weight

 

calibration flag ON. Press *99 to observe flag status.

 

Press * to toggle flag ON

or OFF. With flag set ON, press

 

EXIT. Power-off always resets this flag to OFF.

 

Press the ZERO key once to set the displayed gram weight of the empty bin to zero. BE SURE the load cells are plugged into the controller. Be sure the bin is properly in place

Page 35

Page 34
Image 34
Conair WSB EXIT will exit the sequence and close all outputs, Timed, Press, once, followed by one, component, keys, about