Conair GB Press again, view, the total BATCH COUNT, Display will say BC, #####, Batch Count, Fast

Models: GB WSB

1 119
Download 119 pages 6.25 Kb
Page 31
Image 31

Press again

to

view

the total BATCH COUNT.

 

Display will say (BC

#####).

 

BATCH COUNT

is

the total number of batches

that have run.

This number

will

continue

to grow until it

is manually

cleared to zero,

or

it exceeds its maximum

possible value.

Press again to return to normal operation.

When any of the above totals are being displayed, you may press the CE key to RESET that number to zero. While all four totals can be cleared to zero manually, only the BATCH WEIGHT number can be entered manually.

When the BATCH WEIGHT is being displayed, you may enter a NEW batch weight using the keypad. You must enter a 5 digit number with leading zeros, if necessary. Maximum number that can be entered is "59999".

The unit of weight that will be used is either POUNDS or KILOGRAMS as determined by the *89 option, explained later.

While in operation, when the total is reached, the system will alarm and stop blending if the FLG parameter is set to 00001. The system will alarm but CONTINUE running if the FLG parameter is set to 00002.

Use the ALARM SILENCE button (on the side of the controller) to silence the alarm. Pressing the BTCH key to view the information will also silence the alarm.

If the system is programmed to STOP at the end of a batch, the ALARM SILENCE button MUST be pressed to start blending the next batch. The First press of the ALARM SILENCE button will silence the alarm. The Second press will start the next batch.

NOTE: Fractional cycles are not blended. Total weight may be in over the target by as much as one cycle weight.

The EXIT key will exit the BTCH sequence at any point but will NOT cause the system to start a new batch.

If an additional 120 volt output is desired for an alarm, substitute a 4 or 7 for the 00001. 4 turns on the Additive outlet, 7 turns on component 7 output.

If you have a printer connected, totals will print automatically. (see VIEW, * for details).

FAST:

This key

will allow you

to exceed the

normal blending rate

 

of your unit. Once your system has learned proper flow

 

rates of

each material,

the timing of

each component

 

dispense

is very consistent cycle to cycle. The FAST key

 

allows one or more FAST

REPEAT cycles

to follow a normal

 

calibrated cycle. In a

FAST REPEAT cycle all components are

 

dispensed simultaneously, without any

weights being taken.

 

Errors in dispense amounts will not be detected. These are,

 

in fact,

volumetric dispenses, not gravimetric. These

Page 32