NORMAL OPERATING SEQUENCE - EACH CYCLE

As the sensor is uncovered, the cycle begins. The target weight of a complete batch is 18000, 9000, 4000, 2000, 1000, or 400 grams.

REGRINDS are dispensed first, in their order of size, largest dispense first. After all the Regrind dispenses, the space remaining in the weigh bin is determined.

NATURALS are dispensed second, in their order of size, each at the correct ratio to the others. These dispenses are calculated to fill the bin leaving just enough space for the Additive dispenses. After all Natural dispense are complete the exact weight of all of the NATURALS is determined and, based on this actual dispense weight, the Additive dispenses are now calculated.

ADDITIVES are dispensed last. These dispenses are calculated as a percentage of all the NATURAL components only.

If any dispense fails to reach the requested weight, the process does NOT CONTINUE. The ALARM Strobe light flashes, the Beeper sounds, and the system continues to retry the dispense until the problem is remedied.

The total batch is then dropped into the mixing chamber for blending before entering the throat of the process machine.

SPECIAL FEATURES

To use one of these SPECIAL FEATURES, read about it first. The KEYSTROKE sequence required is given at the end of this section.

To TAG all material usage data with Work Order or Employee numbers for better tracking of material used, read:

KEYPAD, TAG key, and set 2nd digit in the FLG parameter to 1.

To store RECIPES using the RECIPE storage feature, read:

KEYPAD, RECIPE key, and set 3rd digit in the FLG parameter to 1.

To increase throughput, using the FAST key, read:

KEYPAD, FAST key, and set 4th digit in the FLG parameter to 1.

To blend a preset BATCH amount of material and then stop, read: KEYPAD, BATCH key, and set 5th digit in the FLG parameter to 1.

BATCH, RECIPE, FAST, and TAG keys REQUIRE that you read: PARAMETERS, FLG parameter.

To use a lower percentage then 00.1 percent, read:

PARAMETERS, _XT parameter.

To change the MIXER RUN TIME, read:

PARAMETERS, MIX Parameter.

To place UPPER LIMITS on settings, read:

PARAMETERS, _SE Parameter.