Conair GB DS1 00000 Thumbwheel switch override setting DS2, Extrusion control, Rate of, change of

Models: GB WSB

1 119
Download 119 pages 6.25 Kb
Page 49
Image 49

This parameter is the time that the sensor must be uncovered before a cycle will begin.

PRC 00010 Maximum allowable PERCENT rate change per cycle.

This prevents excessive swings in flow rates by the software. Do not change.

STL 00122 Dispense settle TIME before a weight reading is taken.

The time (interrupts) allowed for material to SETTLE in the weigh bin before a weight is taken. Lengthen only to slow the next cycle start, thereby lowering the pile of material in the mix chamber, and, in some cases, improving mixing.

LCL 00080 LOAD CELL limits, low slope, high slope, frequency, zero.

LCH 00120 DO NOT CHANGE except for different weight load cells. LCF 00079

LCZ 00583

The above 4 parameters relate to the characteristics of the LOAD CELLS on your blender. DO NOT CHANGE THEM.

DS1 00000 Thumbwheel switch override setting.

DS2 00000

The above 2 parameters allow external computer inputs to alter the thumbwheel switch settings. They are used on computer controlled dispense systems, using MLAN software.

XCV 00000

Extrusion control

voltage output value

XRC 00001

Rate of

change of

above value

TCV 00000

Takeoff

equipment

voltage output value

TRC 00004

Rate of

change of

above value

XTP 50050

Trip point to force a correction

XAL 00005

Percentage adjustment limit

XUL 00200

Voltage

adjustment limit

The above 7 parameters all relate to Extrusion Control Systems.

MPO 00010 For air drive reciprocating mix motor.

MCT 00000 Monitor Cycle Time

Alarms if normal cycle timing exceeds previous cycle time by a specified amount. Used to detect mechanical failures.

COMPONENT

PARAMETERS

(12 Groups of

13 parameters each)

The first

digit is the

component number.

Component 1 is shown here.

There

are

11 more just

like it.

 

 

1TY =

OFF

DESIGNATES

MATERIAL TYPE

for

this component.

 

Material types are: REG, NAT, ADD,

or OFF=NOT USED.

 

 

(0=OFF, 1=REG, 2=NAT, 3=ADD)

 

 

These MUST be set using the *14 function before the system will

 

 

 

Page

50

 

Page 49
Image 49
Conair GB DS1 00000 Thumbwheel switch override setting DS2, Extrusion control, voltage output value, Rate of, change of