Conair GB, WSB manual LED # 2 will light

Models: GB WSB

1 119
Download 119 pages 6.25 Kb
Page 11
Image 11

LED # 2 will light.

Press "2" repeatedly to observe operation.

REPEAT THIS SEQUENCE for each dispense valve on your WEIGH SCALE BLENDER. Up to 12 outputs are possible numbered 1 through 9, A, B, and C. Only those connected to devices will operate.

AT THIS POINT:

NOTE which component NUMBER is assigned to each

 

hopper. You will

want to know each hopper's

 

correct component

number.

FACING THE CONTROLLER SIDE OF THE BLENDER:

On 9000 and 18000

gram, FOUR hopper compartment systems:

Device 1 is the

NEAR hopper, 2 the

FAR hopper, 3 the LEFT CENTER,

and 4 the RIGHT

CENTER hopper.

 

On 1000, 2000, and 4000 gram, FOUR hopper systems, devices 1, 2, 3, and 4 are counter-clockwise starting with far left corner hopper.

On 9000 and 18000 gram SIX hopper systems, devices 1, 2, 3, 4, 7, and 8 are counter-clockwise starting with far left corner hopper.

ALL MODELS:

Device 5 is the LEFT Panel-front OUTLET.

Device 6 is the RIGHT Panel-front OUTLET.

PRESS "DUMP" KEY

The weigh bin

air solenoid will operate.

 

 

 

LED # 13 will

light.

 

 

 

 

The weigh bin

dump valve will open.

 

 

 

Press "DUMP" repeatedly to observe operation.

PRESS "MIX" KEY

This key controls the mix motor outlet on the

 

 

side of the controller. The mixer motor will run.

 

 

LED # 14 will

light.

 

 

 

 

(Mix blade turns CCW facing the motor shaft.)

 

 

(Mixer switch

must be down; timed position.)

 

PRESS "HOLD" KEY

The Flow Control Valve will operate.

 

 

 

(Under the mix chamber) (This device is optional)

 

 

LED # 15 will

light.

 

 

PRESS "ALARM" KEY

The Strobe light and Beeper will operate.

 

 

 

LED # 16 will

light.

 

 

PRESS "EXIT" KEY

Press twice, to return to normal mode.

 

 

 

Verify normal

mode by observing that there is NO

 

 

letter P in the display (

x).

 

+-----------------------------------------------------------

 

 

 

+

¦

If you have made it this far, congratulations.

¦

¦

 

You have

done well.

 

¦

¦ The load cells and controller are functioning properly. ¦

+-----------------------------------------------------------

 

 

 

+

+----------------------------------------------------------

 

 

 

+

¦

PROCEED TO:

LOAD CELL CALIBRATION

SKIP 2 PAGES

¦

+----------------------------------------------------------

 

 

 

+

Page 12

Page 11
Image 11