Conair GB NATURALS second, ADDITIVES third, Material Runs Out, If ALARM flashes, WEIGH BIN dump

Models: GB WSB

1 119
Download 119 pages 6.25 Kb
Page 85
Image 85

NATURALS second:

The NATURAL dispenses occur next in the sequence. They will be dispensed in order of size, largest to smallest. The letter "N" will appear in the display. The exact weight of all NATURAL dispensed is now determined for calculating the ADDITIVE dispenses.

ADDITIVES third:

The ADDITIVE dispenses occur last in the sequence. Each dispense must meet requirements set by internal parameters or RETRIES will occur and the sequence will not continue.

MATERIAL RUNS OUT:

If any material runs out or is not enough to meet criteria set by parameters then the process will NOT CONTINUE past this component. RETRIES of this dispense will occur indefinitely until the full dispense occurs or power is turned off. The display will FLASH. The ALARM will sound after 4 retries. This number of retries before alarm is based on the ALARM (_AL) parameters. REGRIND may, or may not, be set to cause an alarm when it runs out. See PARAMETERS, _AL, for how to set the ALARM parameters.

If ALARM flashes:

More than four retries of any single component will cause the strobe light ALARM to begin flashing. The component that is causing the alarm will continue to retry the dispense. The display will blink and the first digit in the display will signify which component is causing the problem. To continue with the dispense sequence, you must satisfy the requirements of the dispense or turn power off.

WEIGH BIN dump:

After all dispenses the weigh bin is emptied by the final dump of the weigh bin into the mixing chamber. The dump valve remains open for four seconds. (DTI parameter)

SENSOR covered:

While the sensor is covered, the dump valve remains open to ensure the weigh bin empties completely. Dispensing stops. The dump valve will remain open for as long as the sensor is covered. This will be until the next cycle begins.

FLOW CONTROL Valve: (optional)

The Flow Control Valve under the mix chamber will stay closed for 6 seconds (FCV parameter) immediately following a dispense into the mix chamber. The rest of the time it opens when the sensor is covered, and closes when the sensor has been uncovered for at least two full seconds (based on DLY parameter).

Page 86

Page 85
Image 85
Conair GB, WSB NATURALS second, ADDITIVES third, Material Runs Out, If ALARM flashes, WEIGH BIN dump, SENSOR covered, Page