CONTROLS and OUTPUTS

1.POWER ON switch.

Controls all power to the controller and all outputs. When power is switched off, battery backed-up RAM preserves all internal totals and parameters. All other functions are reset for normal start-up when power is restored.

2.STOP END OF CYCLE / CONTINUE switch

This is the switch that you should use to STOP the system. This switch is wired in series with the level sensor. Turning it off breaks the signal to the computer the same as covering the level sensor with material. This stops the process at the end of a full cycle.

3.IMMEDIATE PAUSE / CONTINUE switch

Causes a computer-controlled immediate pause during a cycle. Dispenses will stop in mid-dispense if necessary. When switched back to CONTINUE, the process continues without any error in amounts dispensed.

4.ALL AIR SOLENOID outputs

There is a single 8 pin or 14 pin (or 17 pin) Amphanol plug located on the front of the control panel. this provides output of all 120 volt (or 24 volt) signals to drive the air solenoids. These power sources are transistor driven and are protected by the 1/2 amp panel fuse. See the wiring diagram section for the correct wiring to each pin.

If more then 7 outputs are to be driven, a 14 pin connector is provided with outputs for components 8, 9, A, B, and C.

If 24 volt solenoids are used, a 17 pin connector is provided.

5.POWER OUTPUTS (receptacles on panel front)

Each outlet puts out 120 volts (240 outside USA) through internal plug- in solid state relays rated and fused at 3 amps. These relay outputs are designed to drive motors or other devices requiring power up to 3 amps each. The LEFT outlet is for component number 5, and the RIGHT outlet is for component number 6.

6.EIGHT CHARACTER DISPLAY

Displays the accumulated total bin weight, in grams, after each dispense. The display flashes when an inadequate dispense has occurred and the dispense is going to be retried. Other information displayed here includes material usage totals, internal parameters, component types and settings and various information prompts to assist the operator.

######

Numbers displayed

are the

total

weight

of

material, in grams,

 

in the bin at

any

time.

The

weight in

the

bin is

updated only

 

after an individual dispense

is

complete.

 

During

the dispense

 

the displayed

weight does

not change.

 

 

 

 

Pin the left most position indicates unit is in PROGRAM mode.

M indicates unit is in MANUAL mode.

1 R 20.0 indicates: Component 1, REGRIND, SETTING of 20 percent.