Conair WSB Load Cell - Weigh Bin Test, To verify correct operation, Start with an empty weigh bin

Models: GB WSB

1 119
Download 119 pages 6.25 Kb
Page 88
Image 88

LOAD CELL - WEIGH BIN TEST

To verify correct operation

This test is to help you determine if the load cells are working correctly, and if the weigh bin and weigh bin hanger are moving freely and registering weight correctly.

Have a pad and pencil ready to write down the weight readings that appear on the display, both before and after each dispense. If you prefer, you can use a printer to record all test data. Have the printer flag (*54) set to ON.

Be in the PROGRAM mode. (*22222).

1.Start with an empty weigh bin.

2.Dispense a very small amount, using the TIMED DISPENSE function: Record the weight display.

Press: TIME, NAT, 040

Wait for dispense then record the new weight.

Wait for test to finish, about 10 seconds. At the end of this test the bin will automatically empty. This is OK.

3.Now, manually add enough pellets to bring bin weight up to the approximate full batch weight. Do this by pressing on the small air solenoid operator pin for NATURAL. Drop in enough pellets to be close to a normal full batch weight, like 2000 or 4000 grams. Exact weight does not matter. We just want to place approximate full batch weight on the load cells.

4.Repeat step 2, recording the weight readings.

5.Do this entire test 3 more times.

From the weight readings, calculate the weight of each dispense from each test.

RESULTS TO EXPECT:

In each test, the first timed dispense, when the bin is empty, should be very close or equal to the second dispense, when the bin is full. Results from all 4 tests should be very similar.

If the second dispense is always less then the first, the load cells are suspect. The enclosures may be full of pellets. Weigh bin interference is also possible. If all dispenses vary widely with no pattern, this is most likely caused by weigh bin interference. Weigh Bin interference is usually visible with close inspection.

Page 89

Page 88
Image 88
Conair WSB Load Cell - Weigh Bin Test, To verify correct operation, Be in the PROGRAM mode. *22222, Press: TIME, NAT, Page