Conair GB Parameters, WEIGHTS are always expressed as GRAMS, Parameter List - Brief Explanations

Models: GB WSB

1 119
Download 119 pages 6.25 Kb
Page 47
Image 47

PARAMETERS

All AUTOWEIGH BLENDER controllers operate according to certain internal PARAMETERS. Because customer requirements vary widely, we have made over 160 parameters accessible for change through the keypad. There is one GENERAL group and twelve COMPONENT groups.

BRIEF explanations are given first. FULL information is given in the section that follows.

NOTE: Values shown here are initial ROM values of a model 940. Initial values for other models are listed at the end of this section.

Parameters are five digits, with leading zeros added.

TIMES are expressed as seconds, minutes, or interrupts. (244 interrupts = 1 second).

WEIGHTS are always expressed as GRAMS.

100 and 200 models use tenths of grams: (xxxx.x). (00010 = 1 gram)

400, 900, and 1800 models; full grams: (xxxxx). (00050 = 50 grams)

PERCENTS are expressed in tenths for settings (0xxx.x),

and full percents for other percentage references (00xxx).

----------------------------------------------------------------------

PARAMETER LIST - BRIEF EXPLANATIONS

GENERAL PARAMETERS (20 parameters) (900 series settings shown)

FLG 00000 turns on the RECIPE, BATCH, FAST, and TAG keys.

These four

keys will NOT

WORK unless you set this parameter.

The

RECIPE

key is for storing up to 99 recipes.

The

BATCH key allows for

filling a barrel or gaylord.

The

FAST key allows a higher output mode.

The

TAG key adds certain

information to all printouts.

MIX 00010

MIX

TIME

 

This parameter times how long the MIX motor runs. The default is set to 00010; 10 seconds of mix.

JOG 03030 JOGS, number and frequency.

This parameter specifies the number of jogs of the mix blade and how often they occur. The default is set to 03030; a jog every 30 seconds, 30 times.

FCV 00006 TIME the Flow Control valve delays before opening (sec.).

This parameter holds each batch in the mix chamber for a time to assure mixing. This is only for units equipped with the optional flow control valve under the mix chamber.

DTI 00004 Weigh bin dump TIME at end of cycle. (seconds)