Conair GB, WSB On 140, 240, 440 and 940 models, If R,N,C,A is selected, PARAMETERS are set, Page

Models: GB WSB

1 119
Download 119 pages 6.25 Kb
Page 39
Image 39

number that will make all natural settings add up to 1000. In this way each NATURAL setting will represent a percent of the total natural blend.

If the sum of natural settings exceeds 1000, component 2 will be set to 000, and the other naturals will be ratioed to each other.

The TY and CS parameters are the ones that are altered.

TY sets TYPE to Regrind, Natural or Additive. CS assigns the thumbwheel swatches. If CS = 40000 the software knows to calculate a setting based on the other naturals such that all settings total 1000.

On 140, 240, 440 and 940 models:

If (R,N,C,A) is selected, PARAMETERS are set:

(1TY = REG) (2TY = NAT) (3TY = ADD) (4TY = ADD) (1CS 30000) (2CS 00100) (3CS 10000) (4CS 20000)

If (N,N,C,A); same as above except: (1TY = NAT) (2CS 40000)

If (N,N,N,A); same as the first except: (1TY = NAT) (2CS 40000) (3TY = NAT)

If (R,N,N,A); same as the first except: (2CS 40000) (3TY = NAT)

On 220 and 420 models:

Changes are the same as above except components 6 and 5 are altered instead of components 3 and 4.

If (R,N,C,A) is selected, PARAMETERS are set:

(1TY = REG) (2TY = NAT) (6TY = ADD) (5TY = ADD) (1CS 30000) (2CS 00100) (6CS 10000) (5CS 20000)

If (N,N,C,A); same as above except: (1TY = NAT) (2CS 40000)

If (N,N,N,A); same as the first except: (1TY = NAT) (2CS 40000) (6TY = NAT)

If (R,N,N,A); same as the first except: (2CS 40000) (6TY = NAT)

All other TYPE parameters are set to (_TY = OFF).

*05 Press (*,0,5) to inhibit the (00=CLEAR) display at the end of the VIEW sequence. Customers using MLAN or G2 software for retrieval of material usage information, may wish to restrict an operators ability to clear the material usage data at the controller. This option allows you to remove the floor operators ability to clear this data. Press * to toggle between (CLEAROFF) and (CLEAR ON).

*11 Press (*,1,1) to enter the correct date and time into the real-time clock. Correct date and time is helpful if you are retrieving information using a printer or are collecting data by computer. Six entries will be requested.

The first display will indicate USA or EUROPE date format. Use the CE key to toggle from one to the other.

USA will cause all dates to be displayed MONTH/DAY/YEAR.