Conair GB Entering, Settings, Press, Display will say, xx.x, Regrind, Natural, Additive, Exit

Models: GB WSB

1 119
Download 119 pages 6.25 Kb
Page 19
Image 19

 

 

ENTERING

SETTINGS

 

Press:

SET

Display will say

(1 R

xx.x)

(Regrind)

 

 

or

(1

N

xxx)

(Natural)

 

 

or

(1

A

xx.x)

(Additive)

1 is Component number. R,N,A is Type.

xx.x is Setting.

Enter a 3 digit setting:

 

 

 

 

 

Regrind settings

= PERCENTAGE of the

ENTIRE MIX

 

 

Natural settings

= RATIO to

OTHER NATURAL SETTINGS

 

 

Additive settings = PERCENTAGE of ALL

the NATURALS

Press:

SET

for the NEXT setting.

 

 

 

 

Repeat this sequence for all

components.

Press:

EXIT

when finished.

 

 

 

When entering settings, remember:

 

 

 

Panel front OUTLETS are always components 5 and

6; (left

and right).

If only one natural is present, any number will

do for a

setting.

Any component set to zero will not dispense.

 

 

THUMBWHEEL ASSIGNMENTS - THIS IS OPTIONAL

You may assign a component to one of the three thumbwheel switches. You might do this for components that you wish to change settings frequently. This is ENTIRELY OPTIONAL.

TO DO SO:

 

 

 

 

 

Press:

SET

Display

will say (1 R xx.x)

 

Press:

A

Display

will say (1 R TW 1)

(Thumbwheel 1)

or

B

Display

will say (1 R TW 2)

(Thumbwheel 2)

or

C

Display

will say (1 R TW 3)

(Thumbwheel 3)

 

 

1

= TOP

switches,

 

 

 

2

= MIDDLE switches,

 

 

 

3

= BOTTOM switches.

 

To RETURN component to KEYPAD entry of the setting:

Press:

CE

Display will return to (1 R 00.0)

Press:

EXIT

when finished.

Page 20