Conair WSB, GB manual Set AUTOMATICALLY when you enter settings, Sets alarm functions, Page

Models: GB WSB

1 119
Download 119 pages 6.25 Kb
Page 64
Image 64

RATIOED to each other and will constitute the ENTIRE mix except for space needed for Regrind and Additives.

ADDITIVE; all the materials that are added to the NATURALS only; color, stabilizer, slip agent, etc.

======================================================================

_CS

(Set AUTOMATICALLY when you enter settings)

_CS parameter stores the current setting that has been entered through the KEYPAD, "SET" function, for this component. You could change it here, but the SET routine is the proper way to alter this number.

This parameter can also be set to ASSIGN this component to one of the three THUMBWHEEL switches. This also is normally done in the SET routine by using the SET key followed by a letter key (A,B, or C).

When set to 10000, 20000, or 30000 the component will follow the TOP, MIDDLE, or BOTTOM thumbwheel switches respectively. The SET routine is the proper way to assign thumbwheels.

In the special case when there are four components, and two or more are naturals, then one NATURAL can have its setting calculated automatically, based on the other natural settings, so that all natural settings total 1000. This is done by setting the CS parameter to

40000. This allows four components to be controlled by only three thumbwheel switches, three assigned, and the forth calculated automatically by default.

If this is a four (or less) component system, then you are using this software because your components are not NATURAL, REGRIND, COLOR and ADDITIVE. Our standard "FOUR" software handles that combination in a simpler, more straightforward way. See KEYPAD, STAR FUNCTIONS, *04 for a rapid way to set up your system for 4 or less components.

======================================================================

_AL

(Sets alarm functions)

_AL Alarm FLAGS. When material runs out, or for some other reason material does not dispense fully, these flags will instruct the controller what to do.

00000 = no alarm, no pause in process, no retries. This is sometimes useful for a Regrind dispense.

00001 to 00009 = sound alarm after specified number of retries and continue retries until successful. The process will not continue until the fault condition is corrected. The last digit determines the number of retries before sounding the alarm. This is appropriate for all important and necessary components.

00011 to 00019 = sound alarm after specified number of retries but then stop the retries and continue with the remainder of the cycle. The alarm will continue until the fault condition is corrected or until the next cycle begins. The last digit determines the number of retries before sounding the alarm. This would be appropriate if you wish to make several attempts at a dispense,

Page 65

Page 64
Image 64
Conair WSB, GB manual Set AUTOMATICALLY when you enter settings, Sets alarm functions, Page