same load cells, the accuracy of these ratios is not affected by zero or full scale errors.

STAR FUNCTIONS available in the MANUAL mode:

*00 Press (*,0,0) to CLEAR ALL DATA fields. These are the material usage totals that are viewed with the VIEW key. If you are tracking material usage, you should record these numbers periodically but clearing these totals is entirely optional and not necessary.

After VIEWING the data or printing of data using the VIEW,* key sequence, a display of (00=CLEAR) will appear for 5 seconds. During this 5 seconds you may reset all data fields to zero by pressing 00. Pressing any other key or waiting 5 seconds will exit this sequence without clearing data.

*99 Press (*,9,9) to set flag to enable Weight Calibration of the Load Cells. Power On will always set this flag to OFF. This flag must be ON before the load cell weight calibration keys, ZERO and FULL WT, will function. With ON flag displayed, press EXIT.

KEYPAD - PROGRAM MODE

In this mode, you may perform ALL of the functions available in MANUAL mode, plus additional functions that alter the logic with which the controller operates.

The PARA key operates in this mode.

STAR FUNCTIONS are available by pressing the "*" key and two numbers.

Just as with the MANUAL mode, you can enter this mode only when the controller is between cycles. The sensor must be covered or the STOP switch must be in the "STOP - END OF CYCLE" position. In the MANUAL mode, no automatic dispensing will occur.

To enter this mode, press "*", then enter the correct password number. The correct password supplied with the unit is "22222". To change this to another 5 digit number of your choice, see (*78). When in the PROGRAM mode, the letter "P" shows at the left end of the display.

The following PROGRAM functions are available in the PROGRAM mode.

PARAMETERS: Press the PARA key to display the table of operating

(PARA) parameters that reside in memory. There are 13 separate groups of parameters. The first group is the GENERAL group and contains 20 GENERAL parameters. The other 12 groups are the COMPONENT groups and contain 13 COMPONENT parameters each.

A FULL EXPLANATION of each PARAMETER can be found in the next section: EXPLANATION of PARAMETERS.

Page 37

Page 36
Image 36
Conair WSB STAR FUNCTIONS available in the MANUAL mode, Keypad - Program Mode, The PARA key operates in this mode, Page