Conair WSB operate. See: TURNING ON OUTPUTS to complete this, Move decimal left on setting, 00010

Models: GB WSB

1 119
Download 119 pages 6.25 Kb
Page 50
Image 50

operate. See: "TURNING ON OUTPUTS" to complete this.

1CS 00000 Thumbwheel assignment or current setting entry.

This parameter reflects the current setting or thumbwheel assignment for this component. No entry is required here.

1AL 00000 Last digit = number of retries before ALARM. 00001 to 00009 = sound alarm, hold process. 00011 to 00019 = sound alarm, continue process.

These parameters set ALARM functions.

When material runs out, or does not dispense fully, these flags instruct the controller what to do. Default settings shown are for Natural, Color, and Additive to alarm, but not Regrind.

1XT 00000

Move decimal left on setting.

These parameters allow entry

of less then (00.1) percent for

a selected component.

 

 

When set

to

"00010"

settings

are

read as X.XX percent.

When set

to

"00100"

settings

are

read as .XXX percent.

1SE 01000 Upper SETTING limits for thumbwheels (0xxx.x). Settings greater than limit are held to limit.

(01000) = 100%

These parameters can SET UPPER LIMITS to the thumbwheels. For color and additive, lower settings may help ensure expensive material is not wasted.

1WT 24000

WT/TI = the rate that will

be used for calculating the

1TI 01952

next dispense time.

 

 

WT = the Weight portion of

the dispense rate, calculated

 

such that WT/TI equals the average of the last two

 

actual dispense rates.

 

 

TI = the TIME portion of the dispense rate. (interrupts)

These change AUTOMATICALLY during

normal operation.

They are Weight and Time portions

of the flow rate calibration.

1MI 00001

Minimum valid dump rate GRAMS/sec. (full or tenth grams)

 

Error correction is bypassed when dispense rate is lower.

On power up, these are always set to 1. After several consistent cycles, they are reset to 80 percent of actual flow rate. These prevent excessive swings in flow rate calculations if material is running out.

1NC 00001 Allowable GRAM error within which NO correction is made.

This is the acceptable error range for each component to prevent hunting. They adjust automatically over an extended time period to match the flow characteristics of each material.

1PT 00000 Reduce the target of the first try dispense.

1RP 00010 PERCENT shortage error that will force a retry.

1RD 00300 GRAM weight shortage error that will force a retry. Page 51

Page 50
Image 50
Conair WSB operate. See: TURNING ON OUTPUTS to complete this, These parameters set ALARM functions, a selected component