AUTOMATIC OPERATION MODE: (normal operation on power up)

VIEW: View Data: date, time, cycles, and each component weight. Press VIEW,* to print data.

RCP: Enter and retrieve stored RECIPES.

BTCH: View BATCH data: Target Weight, Current Portion, Accumulated Total, and Batch Count. CE = clear displayed field.

FAST: Run rapid FAST cycles after a normal weighed cycle.

TAG: Tag Work Order and Operator numbers to all reports.

EXIT: Press to EXIT all sequences from ALL MODES.

SET: Press to review or change settings.

CE: Press to display "raw signal" weight readout for 3 seconds.

MANUAL MODE: Press: "*"; then (11111) or your own 5 digit password.

OPER: Operate all devices manually; open and close valves.

TIME: Operate devices for a selected time period.

CAL: Operate devices to learn rate.

Above keys use 1 through 9, A, B, C, DUMP, MIX, HOLD, ALARM. ZERO: Zero the tare weight with the bin empty.

FULL: Using known weights, enter gram weight to calibrate load cells.

*00 Clear DATA fields.

*99 Set flag to enable weight calibration of load cells.

PROGRAM MODE: Press: "*"; then (22222) or your own password.

SET: Enter settings if access in Automatic mode has been locked out.

PARA: View or change system parameters. Press PARA for next in list, "*" for previous, SET for next table, VIEW for previous table.

STAR FUNCTIONS: Press * and two numbers for the following functions:

*02

Extrusion and Yield Control.

*52

Double dump weigh bin.

*03

Four digit (xx.xx) settings.

*54

Print cycle information.

*04

Simulate FOUR software.

*66

GB/WSB I.D. number (1-255).

*05

Inhibit table clearing.

*69

Regrind as second natural.

*11

DATE - TIME, real-time clock.

*71

Color percent of blend.

*12

Move table from ROM to RAM.

*72

Additive percent of blend.

*23

Move from RAM to EEPROM.

*74

Stop, alarm MAX wt exceeded.

*32

Move from EEPROM to RAM.

*75

Alarm on weight drop.

*14

Set types: REG, NAT, ADD, OFF.

*77

Print parameters.

*25

ROM OK flag, "CE" to clear.

*78

Change program mode PASSWORD.

*33

Special Alarms.

*82

Precision Ratioing.

*44

End cycle - bin full.

*87

VOLUMETRIC operation.

*45

Change MANUAL mode password.

*88

Print display readout.

*47

Totalizer flag.

*89

Select pounds, kilos.

*48

Dispense range xx.x to xxx.

*98

Display raw weight number.

Use "*" key to select readout or toggle flags ON or OFF.