set, (ROM OK ) will be displayed. To turn the flag off, you must select this option, (*25), and, with (ROM BAD) displayed, press the "CE" key. This will clear the flag and it will remain off until another error is detected. The seriousness of the problem will be somewhat indicated by the date and time of the last bad check and how frequently you find it necessary to turn this flag off. Even with an error, your controller may still work perfectly. However, we suggest you request a new program chip from us as soon as possible.

*33 Press (*,3,3,) to turn on a special alarm condition. Press * to toggle between (AL STD) and (AL-BATCH). If you are running using the BATCH key, and (AL-BATCH) is selected, then the ALARM will sound when a batch is completed.

*44 This flag for SPECIAL APPLICATIONS ONLY.

Press (*,4,4) to tell the controller to end a cycle when the weigh bin is FULL. Use the * key to toggle between (END EMTY) or (END FULL).

Normal operation is to end the cycle EMPTY; (END EMTY). The (END FULL) option is only for special installations where the sensor has been relocated BELOW the mix chamber and the purpose of the unit is to calculate exact material usage rates in order to control an extruder.

If you have a flow control valve fitted, this option will increase output of the blender by allowing a cycle to start even though the flow control valve is keeping the sensor covered for an additional 6 seconds.

Leave this flag set to (END EMTY), unless you have specific instructions to do otherwise.

*45 Press (*,4,5, followed by a 5 digit number) to change the PASSWORD number for entering the MANUAL mode. The system is supplied with the number "11111" as the password number. If you wish to restrict use of this mode to only yourself, you may make up your own number and enter it here.

*47 Special function, DISPENSE systems only.

This function alters the range of requested dispense weights. 00.1 to 99.9 is standard. 001 to 999 and 0.01 to 9.99 are optional using this function. Dispense systems are generally used for rotational molding.

*52 Press (*,5,2) to cause the weigh bin dump valve to operate two times. We call this a "double dump". If you have problems with material hanging up in the weigh pan, this may help shake it loose.

Use the * key to toggle between (DBLD OFF) and (DBLD ON). Press EXIT when done.

*54 Press (*,5,4) to set flag for a printout of data after each full dispense cycle. With this flag ON and with a printer