Conair WSB Press * to toggle between FAST ON and FAST OFF, Press EXIT, to exit, This key, number

Models: GB WSB

1 119
Download 119 pages 6.25 Kb
Page 32
Image 32

dispenses take much less time. Throughput is easily doubled in this manner.

This key is NOT FUNCTIONAL unless the 4th digit of the "FLG" parameter is set to 1 (xxx1x). To do this, see the SOFTWARE MAINTENANCE section, PARAMETER TABLE, "FLG".

The shorter mixing time may be a problem. So the number of FAST REPEAT cycles is kept as low as possible. Up to 4 repeats may occur.

Press the FAST key to toggle the FAST flag ON of OFF. When set to (FAST OFF) the FAST mode will not operate. When set to (FAST ON) every normal calibrated dispense will be followed by up to 4 FAST repeat dispenses.

This series of 4 dispenses is terminated as soon as the sensor is covered, which indicates the blender has "caught up". The next cycle will then be a weighed cycle, followed by the required series of fast cycles to catch up again.

Press * to toggle between (FAST ON) and (FAST OFF).

Press EXIT, to exit.

When the FAST mode is in operation, the display ( FAST) will flash intermittently.

SETTING: Press once and the current setting of component 1 is

(SET) displayed. Display will say (1 X xx.x). X is material type, either R, (REGRIND); N, (NATURAL); or A, (ADDITIVE). xx.x is the current setting.

Press SET to step forward through all the settings.

Press * key to backup in the list.

NEW settings may be entered directly.

REGRIND and ADDITIVE settings are expressed as percents, up to 99.9 percent. NATURAL is any number you wish (usually weight). It is used to establish RATIOS with all other NATURAL entries. When only one material is designated as a NATURAL, the value of it's setting has no meaning, except that it must be set to some value to operate.

If you wish to restrict the entry of settings to the PROGRAM mode only, (password required), you may do so by altering the _SE parameter for each component that you wish to "lock out". See MAINTENANCE SECTION, PARAMETERS, _SE parameter.

TAG:

This key

allows two

pieces of

information to

be "tagged"

 

onto all

data that is either printed or retrieved through

 

the computer port.

The items

are WORK ORDER

number and

 

OPERATOR

number.

 

 

 

This key is NOT FUNCTIONAL unless the 2nd digit of the "FLG" parameter is set to 1 (x1xxx). To do this, see the SOFTWARE MAINTENANCE section, PARAMETER TABLE, "FLG".