such as regrind, but you wish the process to continue even without the component.

00021 to 00029 = same as 1 to 9, Stop Process, Sound Alarm, but NO more retries. Just sound alarm and wait. Press the RESET button to clear alarm and start the retries again. Appropriate ONLY if you absolutely want operator intervention to occur when material runs low. In other words you do not want any automatic loading or other correction to allow the process to continue.

The first three digits of this parameter (_AL xxx00) may be used to STOP and ALARM the blender if an over dispense occurs by the number of grams specified. For example, CAL 02004 will cause the system to STOP and ALARM if the COLOR dispense is 20 grams over target.

(C - OVER) will be displayed. Use PAUSE (or POWER OFF) to reset the Alarm condition. If a printer is connected, a standard cycle printout will occur.

======================================================================

_XT

(Allows a setting entry of less then 00.1)

_XT, is a number that will alter the value of the setting that you enter. The value of the XT parameter, is divided into the setting, thereby reducing the setting's value. The only valid entries are 10 and 100. When set to "00010" the decimal point is moved to the left one place and the setting is read as X.XX percent. When set to "00100" the decimal point is moved to the left two places and the setting is read as .XXX percent. This allows closer control where a requested dispense is less than 1 percent. When set to "00000", this parameter has no effect.

======================================================================

_SE

(Use to lock out high settings or limit access)

_SE is the upper SETTING limits for this component. This allows a reasonable cap to be set for each component so that an operator cannot accidentally set the controls to an excessively high setting. For additives, these limits will ensure that expensive material is not wasted. Settings that are greater than the limit are held to the limit.

EXAMPLE: If the highest color usage in your plant is 6%, then you can enter this upper limit in the parameter table. Since settings are stored as 1/10's of percent (##.#), the parameter would be:

 

 

_SE

00060

 

 

 

 

Any setting

above 060 is

held to

6 percent.

When a

1 is

entered as the first

digit

of this parameter,

(_SE 1xxxx), setting

entries can

only

be made from the program mode.

In this way

access is limited

to

only

those

who know the password.

======================================================================

_WT and _TI

(Set AUTOMATICALLY by the CALIBRATE routine)

_WT, and _TI parameters are related to the flow rate or dispense rate of each material. These can be changed manually, set by the RATE