PART I - ASSEMBLY

¦

+

--------------------------------------------------------------------

+

ASSEMBLY and INSTALLATION INSTRUCTIONS

CAUTION: LOAD CELLS ARE EASILY DAMAGED.

If the FRAME is dropped from TWO FEET, the load cells WILL BE DAMAGED. THE WARRANTY DOES NOT COVER DAMAGED LOAD CELLS.

The following items have been shipped to you:

1.FRAME and HOPPER assembly: (bolted to skid)

2.CONTROLLER BOX: with the instruction manual.

3.FEEDER BOX: contains a COLOR or ADDITIVE feeder: optional.

4.FLOW CONTROL ASSEMBLY: optional

5.FLOOR STAND or VACUUM TAKEOFF ASSEMBLY: optional

RED INSTRUCTION STICKERS will assist you during assembly.

LIFT HANGERS are available to allow lifting the blender with a strap or chain. Call us if you require them.

1A. If your

unit

is

to be MACHINE mounted:

For GB/WSB

GBM, 100, 200,

and 400 series models:

Two

ways

to

do this are

suggested ON THE NEXT PAGE: (4a)

The LEFT diagram shows the FRAME and SLIDE GATE both drilled with the proper bolt pattern for your machine and THROUGH- BOLTED to your press.

The RIGHT diagram shows only the 10 x 10 steel slide-gate plate drilled for your bolt pattern and bolted to your press. The FRAME is then bolted to it using the existing 8 x 8 inch bolt pattern holes and bolts provided. With this method, bolt head clearance holes are required in the poly-pro slide gate plate. This mounting works well on smaller machines.

For GB/WSB 900 and 1800 series models:

An additional machine mount adaptor plate may be required. If you have ANY DOUBT about the STABILITY of the unit when bolted directly to your machine throat, please call us for advice.

NOTE: When choosing proper orientation, be sure to retain access to the controller and weigh chamber, clearance for hinged doors, and access to removable feeder hoppers.

1B. If your unit is STAND mounted:

A stand is provided and your unit will bolt directly to it. An assembly DIAGRAM is provided on the following pages.

An air operated FLOW CONTROL ASSEMBLY is provided for dispensing into a container. The purpose of this unit is to allow time for mixing to occur after each dispense. This flow valve keeps the mix chamber full to just below the sensor. This assembly bolts directly to the bottom of the Blender frame.