DIAGNOSTICS - for the CHECK OUT PROCEDURE

If display fails to come on at all: check for power at outlet.

Check the 1/2 amp panel front fuse.

If first display says ( FOUR ), then this is NOT the correct manual for this software. Obtain and use a FOUR software manual.

Possible model numbers are:

GBM, 140, 14R, 220, 240, 24R, 420, 440, 44R, 940, 184. If model number is not correct for you unit:

see the next page, SELECTING CORRECT MODEL.

If display shows randomly drifting numbers: check to see load cells are plugged in.

If display shows about (- 1250.0) or ( -4500):

check that the weigh bin is in place properly.

If display is steady but not near zero:

An over stressed load cell will display a permanently high or low reading. Recalibrate load cells; next section.

If there is no response from the display when the bin is touched: check for damaged wires to load cells.

check that load cell plug screws are secure.

If response is not sensitive or does not return to its start point: check for interference around weigh bin.

If pressing * does not display (PASSWORD):

you are not in the normal power-up mode or the keypad doesn't work. Normal mode is indicated by the ABSENCE of the letter M or P at the left of the display.

If display says INVALID after entering the password number:

you pressed the wrong keys or the password number has been changed and it is no longer 22222. Call us for help.

If an air solenoid does not operate: check the 1/2 amp fuse.

check solenoid cable connected properly and fully seated. check mix chamber door closed, safety interlock engaged.

If a slide or dump valve does not open:

check the air supply and regulator adjustment: (minimum 20 psi, 80 psi (5.5 bar) recommended).

check for proper air line connection to cylinder.

If an auger feeder motor does not run: check the 3 amp fuse.

check that the motor is plugged into the proper outlet. check for faulty motor by plugging it into a known source of 110 volt A.C. power (240 volt outside U.S.).