SET V25BIS RIDTR RidtrDelay
Defines the amount of time between receipt of ring signal detection and the issuance of Data Terminal Ready (DTR) on. If this delay is exceeded, the call is abandoned. This delay must not exceed the value for SET V25BIS RING.
Range:
SET V25BIS HANGUP HangupDelay
Defines the amount of time after the line is disconnected before a new command can be issued. This is used to give the modem enough time to prepare to accept other commands.
Range:
Default: 2.
SET V25BIS DSRLOSS DSRlossDelay
Defines how long Data Set Ready (DSR) must be lost to determine that there has been a valid loss of carrier, not just a temporary fluctuation. A valid loss of DSR usually means the modem will hang up.
Range:
Default: 1500.
SET V25BIS RING RingDelay
Defines the permitted delay between rings. If this timer is exceeded, it is assumed that the caller has hung up.
Range:
Default: 5000.
SET V25BIS TRANSITION TransitionDelay
Defines the maximum delay for Data Set Ready (DSR) to be set to OFF after Data Terminal Ready (DTR) is set to OFF. Normally DTR is set to OFF upon a disconnection request.
Range: 0-65 seconds.
Default: 2.
SET V25BIS OFFHOOK OffHookDelay
Defines the delay before going into data transfer mode.
Range:
Default: 2000.
SET V25BIS CTSON ProgMessDelay
Defines the delay between sending a command message to the V.25bis modem and its acceptance. If this timer is exceeded then the command message is returned with an error code.
Range:
Default: 200.
SHOW V25BIS CONFIGURATION
Displays the configuration settings for the V.25BIS dialer.
Command Line Interface | 123 |