Eicon Networks 1530 manual Range 0-65 seconds Default

Models: 1530

1 162
Download 162 pages 34.57 Kb
Page 123
Image 123

SET V25BIS RIDTR RidtrDelay

Defines the amount of time between receipt of ring signal detection and the issuance of Data Terminal Ready (DTR) on. If this delay is exceeded, the call is abandoned. This delay must not exceed the value for SET V25BIS RING.

Range: 0-30000 milliseconds. Default: 1000.

SET V25BIS HANGUP HangupDelay

Defines the amount of time after the line is disconnected before a new command can be issued. This is used to give the modem enough time to prepare to accept other commands.

Range: 0-65 seconds.

Default: 2.

SET V25BIS DSRLOSS DSRlossDelay

Defines how long Data Set Ready (DSR) must be lost to determine that there has been a valid loss of carrier, not just a temporary fluctuation. A valid loss of DSR usually means the modem will hang up.

Range: 0-10000 milliseconds.

Default: 1500.

SET V25BIS RING RingDelay

Defines the permitted delay between rings. If this timer is exceeded, it is assumed that the caller has hung up.

Range: 1-9000 milliseconds.

Default: 5000.

SET V25BIS TRANSITION TransitionDelay

Defines the maximum delay for Data Set Ready (DSR) to be set to OFF after Data Terminal Ready (DTR) is set to OFF. Normally DTR is set to OFF upon a disconnection request.

Range: 0-65 seconds.

Default: 2.

SET V25BIS OFFHOOK OffHookDelay

Defines the delay before going into data transfer mode.

Range: 0-4000 milliseconds.

Default: 2000.

SET V25BIS CTSON ProgMessDelay

Defines the delay between sending a command message to the V.25bis modem and its acceptance. If this timer is exceeded then the command message is returned with an error code.

Range: 200-4000 milliseconds.

Default: 200.

SHOW V25BIS CONFIGURATION

Displays the configuration settings for the V.25BIS dialer.

Command Line Interface