Connection Menu > Connection Group (when protocol is set to X.25)
Remote DTE Address
Defines the remote X.25 address the Eicon 1530 calls to establish the connection.
Range:
When the X.25 connection type is set to permanent (see the ‘Connection Type’ setting), this parameter defines the VC number used.
Compression Type
Defines the type of compression used for X.25 traffic.
•NONE: No compression.
•EICON: Compression negotiation: CCP (Compression Control Protocol). Compression
algorithm:
•BAY: Compression negotiation: WCP. Compression algorithm: Magnalink. Check mode:
LCB. Dictionary size: 8K or 32K.
•CISCO: Compression negotiation: None. Compression algorithm:
Connection Type
Defines the type of connection that will be established with the remote device.
•TWOWAY: Both the Eicon 1530 and remote device can initiate the connection.
•INCOMING: The remote device must initiate the connection.
•PERMANENT: A PVC is permanently established between two destinations. No call setup is required.
Facilities
Sets the X.25 facilities used to establish an X.25 call with this profile. Encode facilities as a hexadecimal string of characters separated by commas, colons, or hyphens. Maximum length is 14 bytes. For example: 42,07,07
User Data
Specifies the call user data the device will include when establishing an X.25 call. Encode call user data as hexadecimal digits separated by commas, colons, or hyphens. Maximum length is 16 bytes. For example: 42,07,07
Idle Timer
Defines the maximum amount of time an X.25 connection can be idle before the connection is dropped.
Range:
Default: 20 seconds.
Web Interface Settings Glossary | 65 |