SET PROFILE PVC num

Defines which PVC (Permanent Virtual Circuits) to be used. This is used only when you select PERMANENT connection type. (See SET X25 CONNTYPE)

Range: 1-32. Default: First unused PVC number.

Note: Note: The maximum value should not be greater than total of PVCs.

SET X25 NODETYPE { DTE DCE }

Defines if the Eicon 1530 functions as DTE (Data Terminal Equipment) or DCE (Data-Circuit terminating Equipment). Consult your network subscription for the proper setting.

Default: DTE.

DTE: Use when connected to an X.25 network, or to another computer configured as DCE.

DCE: Use when connected to another computer configured as DTE.

SET X25 CUD callUserData

Specifies the call user data the device will include when establishing an X.25 call.

callUserData: Encode call user data as hexadecimal digits separated by commas, colons, or

hyphens. Maximum length is 16 bytes. For example: 42,07,07

SET X25 FACILITIES hexstring

Sets the X.25 facilities used to establish an X.25 call with this profile.

hexstring: Encode facilities as a hexadecimal string of characters separated by commas, colons,

or hyphens. Maximum length is 14 bytes. For example: 42,07,07

ENABLE X25 SEQUENTIAL

DISABLE X25 SEQUENTIAL

Enables/disables sequential assignment of virtual circuits. Most X.25 networks assign virtual circuits sequentially. However, some networks, such as British Telecom's Packet Switch Stream, assign virtual circuits non-sequentially using Logical Channel Group numbers. If this is the case, you must define the starting LCN (Logical Channel Number) for each group of virtual circuits (PVC, IVC, TVO, and OVC).

Default: Enabled.

SET X25 PVC number startAddress

Defines settings for PVCs (Permanent Virtual Circuits). A PVC is permanently established between two destinations. No call setup is required.

number: Total number of PVCs set by your X.25 network subscription.

startAddress: The starting LCN (Logical Channel Number) to use for the first PVC. Only valid if the sequential assignment of virtual circuits is enabled.