Instruction Manual

IM-106-340, Rev. 4.0

May 2006

Figure 9-8. Heater Strut

Assembly

V-Deflector

Ceramic Support Rod

Ceramic

Diffuser Cell Flange

Assembly

Heater

Oxymitter 4000

Wire

Loop

22220050

13.For units with remote electronics, install the probe head as follows:

a.See Figure 9-9.Make sure that the O-ring is in good condition. Seat the O-ring in the mating groove of the probe.

b.Insert the probe signal cables into the housing.

c.Turn the conduit ports of the housing to the CAL and REF gas ports side of the probe and position the housing on the probe.

d.Install and tighten four screws (2, Figure 9-4).

e.Reconnect the probe signal cables to the probe signal and heater wire connectors, Figure 9-9.Make sure the connectors are secure.

f.Install and tighten cover.

14.Follow the instructions in "Removal and Replacement of Probe" to install the Oxymitter 4000 into the stack or duct.