Oxymitter 4000

Figure 2-7. Orienting the

Optional Vee DeflectorGas Flow

Direction

Vee

Deflector

Apex

Diffusion

Element

Filter

Setscrew

Vee

Deflector

22220020

Remote Electronics Installation

Uninsulated stacks or ducts may cause ambient temperatures around the electronics to exceed 185°F (85°C), which may cause overheating damage to the electronics.

8.If insulation is being removed to access the duct work for Oxymitter 4000 mounting, make sure the insulation is replaced afterward (Figure 2-8).

For an Oxymitter 4000 equipped with remote electronics, install the probe according to the instructions in "Probe Installation". Install the remote electronics unit on a stand pipe or similar structure, Figure 2-2.