Power Requirements:

 

Probe Heater

175 W nominal

Electronics

10 W nominal

Maximum

500 W

Fisher-Rosemount has satisfied all obligations coming from the European legislation to harmonize the product requirements in Europe.

1-8 HAZARDOUS AREA CERTIFICATIONS

a.Hazardous Area Oxymitter 4000 with Integral Electronics

KEMA/ATEX

II 2 G EEx d IIB+H2 T6 (Elect Comp) / T2 (Probe)

CSA

Class I, Division 1, Groups B, C, D T2

 

 

Class I, Zone 1, Ex d IIB+H2 T2

 

 

Class I, Zone 1, AEx d IIB+H2 T2

 

FM

Class I, Division 1, Groups B, C, D T2

 

 

Class I, Zone 1, AEx d IIB+H2 T2

 

b. Hazardous Area Oxymitter 4000 with Remote Electronics

 

KEMA/ATEX

II 2 G EEx d IIB+H2 T2

(Remote Probe)

 

II 2 G EEx de IIB+H2 T6

(Remote Electronics)

CSA

Class I, Zone 1, Ex d IIB+H2 T2

(Remote Probe)

 

Class I, Zone 1, Ex de IIB+H2 T6

(Remote Electronics)

 

Class I, Zone 1, AEx d IIB+H2 T2

(Remote Probe)

 

Class I, Zone 1, AEx de IIB+H2 T6

(Remote Electronics)

FM

Class I, Zone 1, AEx d IIB+H2 T2

(Remote Probe)

 

Class I, Zone 1, AEx de IIB+H2 T6

(Remote Electronics)