Instruction Manual
Hazardous Area Oxymitter 4000
|
|
O2 Range: | 0 to 10% O2, 0 to 25% O2, 0 to 40% O2 (via HART) |
Standard | |
Accuracy | ±0.75% of reading or 0.05% O2, whichever is greater |
System Response to Calibration Gas | Initial – less than 3 sec., T90 – less than 8 sec. |
Temperature Limits: |
|
Process | 0° to 704°C (32° to 1300°F) up to 1300°C (2400°F) with |
| optional accessories |
Electronics Housing | |
Electronics Package | |
| electronics inside instrument housing, as measured by |
| a HART communicator or Rosemount Asset Management |
| Solutions software |
Local Operator Interface | |
| |
| above 70°C (158°F) inside instrument housing, the infrared |
| keypad will cease to function, but the Oxymitter 4000 will |
| continue to operate properly.] |
Probe Lengths | 18 in. (457 mm), 3 ft (0.91 m), 6 ft (1.83 m) |
Mounting and Mounting Position | Vertical or horizontal; |
| a spool piece (P/N 3D39761G02) is available to offset |
Materials: | transmitter housing from hot ductwork. |
| |
Probe | Wetted or welded parts - 316L stainless steel (SS) |
| |
Electronics Enclosure | |
Calibration | Manual, |
Calibration Gas Mixtures Recommended.. | 0.4% O2, Balance N2 |
Calibration Gas Flow | 8% O2, Balance N2 |
5 scfh (2.5 l/m) | |
Reference Air | 0.5 scfh (0.25 l/hr), clean, dry, |
Electronics | (20.95% O2), regulated to 5 psi (34 kPa) |
NEMA 4X, IP66 with fitting and pipe on reference exhaust | |
| port to clear dry atmosphere |
Line Voltage | |
Pollution Degree | 2 |
Over Voltage Category | II |
Relative Humidity | 5 to 95% |
Signals: |
|
Analog Output/HART | |
| maximum load |
Logic I/O | |
| output or as a |
| IMPS 4000 or SPS 4000. |
| |
| Conduit port — 3/4 |
| and logic I/O signal lines) |
Rosemount Analytical Inc. A Division of Emerson Process Management |