Instruction Manual

IB-106-340C Rev. 4.1 July 2004

Hazardous Area Oxymitter 4000

Table 1-1. Product Matrix

OXT4C

OXYMITTER 4000 - EXPLOSION PROOF - IN SITU OXYGEN TRANSMITTER

Explosion Proof Oxygen Transmitter - Instruction Book

Code Sensing Probe Type with Flame Arrestor

1Ceramic Diffusion Element Probe (ANSI 3 in. 150 lbs)

2Snubber Diffusion Element (ANSI 3 in. 150 lbs)

3Ceramic Diffusion Element Probe (DIN 2527) - 1/4 in. Tube Fittings

4Snubber Diffusion Element (DIN 2527) - 1/4 in. Tube Fittings

5Ceramic Diffusion Element Probe (JIS)

6Snubber Diffusion Element (JIS)

7Ceramic Diffusion Element (ANSI 3 in. 300 lbs)

8Ceramic Diffusion Element (ANSI 4 in. 300 lbs)

Code Probe Assembly

018 in. (457 mm) Probe

118 in. (457 mm) Probe with 3 ft (0.91 m) Bypass

218 in. (457 mm) Probe with Abrasive Shield(1)

33 ft (0.91 m) Probe

43 ft (0.91 m) Probe with Abrasive Shield(1)

56 ft (1.83 m) Probe

66 ft (1.83 m) Probe with Abrasive Shield(1)

Code

Mounting Adapter - Stack Side

0No Adapter Plate (“0” must be chosen under “Mounting Adapter - Probe Side” below)

1New Installation - Square weld plate with studs

2Model 218 Mounting Plate (with Model 218 Shield Removed)

3Competitor’s Mount(2)

Code Mounting Adapter - Probe Side

0No Adapter Plate

1Probe Only (ANSI)

2New Bypass or New Abrasive Shield (ANSI)

4Probe Only (DIN)

5New Bypass or New Abrasive Shield (DIN)

7Probe Only (JIS)

8New Bypass or New Abrasive Shield (JIS)

Code Electronic Housing and Filtered Customer Termination - NEMA 4X, IP66

11HART® Integral Electronics, Standard Filtered Termination, ATEX Certification

12HART® Integral Electronics, Transient Protected Filtered Termination, ATEX Certification

13HART® Remote Electronics (requires cable), Standard Filtered Termination, ATEX Certification

14HART® Remote Electronics (requires cable), Transient Protected Termination, ATEX Certification

21HART® Integral Electronics, Standard Filtered Termination, CSA/FM Certification

22HART® Integral Electronics, Transient Protected Termination, CSA/FM Certification

23HART® Remote Electronics (requires cable), Standard Filtered Termination, CSA/FM Certification

24HART® Remote Electronics (requires cable), Transient Protected Termination, CSA/FM Certification

OXT4C

3

3

1

1

11

Example

1-14 Description and Specifications

Rosemount Analytical Inc. A Division of Emerson Process Management

Page 44
Image 44