Digital Sync Validation Processing (DSVP)

Command

ASCII Command

Response

Additional Description

(Host to Switcher)

(Switcher to Host)

 

 

 

 

 

 

 

 

Digital Sync Validation Processing (DSVP)

 

 

View connections

0LS

X2# X2# X2#...X2#n]

Each X2# response indicates

 

 

 

presence or absence of

horizontal and vertical sync on an input, starting from input 1. n is the maximum number of inputs on your model.

I/O Grouping

NOTE: The group that is assigned in each of the following I/O grouping commands (X%) must be 1, 2, 3, 4, or 0 (not grouped).

Write input grouping

E X% X%... X%nI}

Example:

E 40...2I}

DXP DVI Pro 88

DXP HDMI 88

GriX% X% X%...X%n]

 

 

 

 

Each X% entry is the group

 

 

 

 

 

 

 

number assigned to an input

 

 

 

 

 

 

 

position, starting from input 1.

 

 

 

 

 

 

 

n = the maximum number of

 

 

 

 

 

 

 

inputs for this model.

Input 1 in

 

 

Input 2 not

 

Input 8 in

group 4

 

 

grouped

 

 

 

group 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Response #s = group: Gri 4 0 1 3 3 0 0 2

Input:

1

 

2

 

3

 

4

 

5

 

 

6

 

7

 

8

 

 

Write output grouping

E X% X%...X% O}

Read input grouping

E I}

Gro X% X% X%...X%n]

X% X% X%...X%n]

Input 1 – group 4

input 2 – group 0 (ungrouped) input 8 – group 2

Each X% entry is the group number assigned to an output position, starting from output 1. n = the maximum number of outputs for this model.

Each X% entry is the group number assigned to an input position, starting from Input 1. n = the maximum number of inputs for this model.

Example:

E I}

DXP DVI Pro 88

 

DXP HDMI 88

 

Read output grouping

E O}

Input 1 in

 

 

Input 3 Not

 

Input 8 in

Group 1

 

 

Grouped

 

 

Group 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Response = group:

1 1 0 3 3 0 0 0

 

Input:

1

2

3

4

5

6

7

8

 

X% X% X%...X%n]

 

 

 

 

 

 

Each X% entry is the group

 

 

 

 

 

 

 

 

 

number assigned to an output

 

 

 

 

 

 

 

 

 

position, starting at Output 1.

 

 

 

 

 

 

 

 

 

n = the maximum number of

 

 

 

 

 

 

 

 

 

outputs for this model.

NOTE: X% = Group number

1

4. 0 = ungrouped

X2# = Sync present

0

= no sync detected; 3 = signal detected

DXP DVI, DXP DVI Pro, and DXP HDMI Series • SIS Configuration and Control