To perform a soft reset of the switcher:

1.Use a small Philips screwdriver to press and hold the rear panel Reset button until the front panel Video and Audio buttons blink once (for an events reset), twice (for a system reset), or three times (for an absolute reset).

Press and hold the Reset button.

Events Reset

RESET

 

(Mode 3)

 

Reset LED flashes once.

3 seconds

RESET

 

Release, then immediately press and release again.

RESET

Front panel I/O buttons flash once.

I / O

VIDEO

AUDIO

Press and hold

Reset LED flashes twice.

the Reset button.

IP Settings

RESET

6 seconds

RESET

 

 

Reset

 

 

 

(Mode 4)

 

 

 

Release, then immediately press and release again.

RESET

Front panel I/O buttons flash twice.

I / O

VIDEO

AUDIO

Press and hold the Reset button.

Absolute Reset

RESET

 

(Mode 5)

 

Reset LED flashes

three times.

9 seconds

RESET

 

Release, then immediately press and release again.

RESET

Front panel I/O buttons flash three times.

I / O

VIDEO

AUDIO

Figure 62. Soft Resets

2.Release the Reset button and then immediately press and release the Reset button again. Nothing happens if the second momentary press does not occur within

1 second.

DXP DVI, DXP DVI Pro, and DXP HDMI Series • Operation

43

Page 49
Image 49
Extron electronic DXP DVI PRO manual Soft Resets