Extron electronic DXP DVI PRO manual IP Setup, IP Settings/Options Window

Models: DXP DVI DXP DVI PRO

1 137
Download 137 pages 18.49 Kb
Page 85
Image 85
IP Setup

IP Setup

The IP Settings/Options window lets you view and, if connected via the RS-232 or RS-422 link or logged on via the Ethernet port as an administrator, edit settings unique to the Ethernet interface. To display the IP Settings/Options window, select IP Options from the Tools pull-down menu.

Figure 79. IP Settings/Options Window

ATTENTION: Editing the following fields or check boxes on the IP Settings/Options screen while connected via the Ethernet port can immediately disconnect your computer from the switcher:

Matrix IP Address

Gateway IP Address

Subnet Mask

Use DHCP check box

Administrator Password

NOTES: Extron recommends editing the settings on this screen using the RS-232 or RS-422 link and protecting the Ethernet access to this screen by assigning an administrator password to qualified and knowledgeable personnel only.

When the control program is connected to the DXP via RS-232 or RS-422, the Administrator Password and User Password fields are not masked. If a password has been inadvertently changed to an unknown value, you can look up and, if desired, change a password in this window without knowing the current password.

See “IP Addressing” on page 125 for basic information about IP addresses.

DXP DVI, DXP DVI Pro, and DXP HDMI Series • Matrix Software

79

Page 85
Image 85
Extron electronic DXP DVI PRO manual IP Setup, IP Settings/Options Window