Fostex D2424 manual Controller Connection Cable, Record track select key

Models: D2424

1 147
Download 147 pages 44.91 Kb
Page 11
Image 11

 

Model D2424 Reference Manual (Names and Functions)

 

 

Detachable Controller section

 

 

 

 

 

 

1

2

3

4

5 6

7

 

 

11 13

 

 

8 9 10 12 14 15

 

 

 

 

AUTO RTN

 

 

AUTO RTN

 

 

 

 

 

 

 

 

AUTO PLAY

CLIPBOARD

 

AUTO PUNCH

 

PGM SEL

EXIT/NO

EXECUTE/YES

 

 

 

 

IN OUT

START

IN

OUT

END

 

 

24TRACK DIGITAL RECORDER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PREVIEW

 

 

 

EJECT

CHASE

 

 

 

 

 

 

 

 

CHARACTER

 

LOCATE MEMORY

16

 

 

 

 

EDIT

SETUP

UNDO/REDO

PREV

NEXT

DISP SEL

STORE

RECALL

36

 

 

SHIFT

TC READY

TC GEN

M.UNDO

PREV TC

NEXT TC

TIME BASE SEL

HOLD

 

18

 

 

 

TAKE

 

 

 

 

 

 

 

 

24bit

AUTO

REHEARSAL

 

LOCATE

VARI PITCH

 

 

 

17

 

 

96kHz

PUNCH

 

 

 

 

 

 

 

 

 

 

 

OPTICAL

 

 

 

 

P.EDIT

 

 

 

 

 

 

 

RECORD TRACK

 

 

RECORD

STOP

PLAY

REW

F FWD

35

1/9/17 2/10/18 3/11/19 4/12/20

5/13/21

6/14/22 7/15/23 8/16/24

TRACK SHIFT

 

 

 

 

19

FOOT SW

 

 

 

 

 

 

 

 

 

ENVELOPE

 

ALL INPUT

ALL READY

 

 

 

 

 

ACCESS

9-16

17-24

TRACK SHIFT

 

CLIPBOARD PLAY

 

 

 

 

 

 

 

 

LOCATE ABS 0

 

 

 

 

 

 

 

 

LOCATE REC END

 

 

30 28 26 24 22 20

34 33 32 31 29 27 25 23 21

1. Controller Connection Cable

Connect this cable to the recorder controller connection jack.

2.Record track select key

[RECORD TRACK/ENVELOPE]

"SAFE-READY" of the recording track can be selected (The track can be selected by shifting to 1-8, 9-16 or 17-24 with the [TRACK SHIFT] key.

If the select key is pressed once, that track will be in the READY state and the track display () will blink. It will change to SAFE if pressed again and the track display will be extinguished.

When recording is started from the READY mode, the blinking track display will light.

If the [RECORD] button only is pressed from the READY mode, the READY track only will enter input monitor mode, and the recording level can be adjusted. If the [RECORD] button is pressed once again, the D2424 will return to repro monitoring.

*All TRACK SHIFT LED extinguished: Tracks 1-8 can be selected.

*"9-16" are lighted: Tracks 9-16 can be selected.

*"17-24" are lighted: Tracks 17-24 can be selected.

All real track input monitors can be switch on or off each press of this key while pressing [SHIFT] key. When all tracks are set to input monitor, the ALL INPUT LED will light.

4. Auto Play/Auto Return key [AUTO RTN/PLAY]

Pressing this key repeatedly will change Auto Play mode, Auto Return mode, and Repeat mode On/Off as follows: ( : LED off, : LED light up)

AUTO RTN

Auto Return/ Auto Play mode is OFF.

AUTO PLAY

(No indication)

AUTO RTN

AUTO PLAY

Auto Play mode is ON.

 

 

 

 

 

(Only the AUTO PLAY LED is lit. )

 

 

 

 

 

 

 

 

 

 

If any select key is pressed together with the [SHIFT] key, the envelope function of that track can be

AUTO RTN

AUTO PLAY

Auto Return mode is ON.

executed. This key is also used for editing such as copy paste, move paste and erase.

*Refer to page “28” for details about the reproduction monitor and the input monitor.

*Refer to page “60” for details about the envelope function.

*Refer to page “66” for details about the copy/paste and move/paste function.

(Only the AUTO RTN LED is lit. )

AUTO RTN

Auto Repeat mode is ON.

AUTO PLAY

(Both AUTO PLAY and AUT RTN LEDs are lit. )

Auto Play mode:

In this mode, playback will start automatically after the START point is located. This function is effective at any locate points other than the REC END point.

3. Track shift key [TRACK SHIFT/ALL INPUT]

When selecting a recording track, this is pressed to shift to the selectable track. With each pressing of the key, the TRACK SHIFT LED will sequentially switch in order of: "Extinguish" - "Lighting of 9-16"

-"Lighting of 17-24" - "Extinguish" to indicate the modes listed below

Auto Return mode:

When the END point is reached during playback, the START point is automatically located in this mode. This function is effective only when the START and END points have been specified.

<Note>

The Auto Return function is works only during playback. In the recording mode, the START point will not be located automatically when the END point is reached.