<Note>

Connecting the recorder to an external digital device via both digital input and output jacks may generate a digital loop.

*If the connected external device has only a COAXIAL (RCA pin) jack for digital input, use an optional Fostex COP-1/96k (optical/coaxial converter).

<Note>

Data on the additional tracks cannot be digitally recorded to the external device as it is. To output digital data from the additional track, move it to the real tracks first, then output it to the external device (using the Track Exchange function). For more information on the Track Exchange function, see page “72.”

Selecting a recording Program

1.If you already have multiple Programs, select the desired Program using the Program Select function.

*See page “35” for more information on the Program Select function.

Setting the digital output

Use the digital output setup menu in Setup mode to assign output tracks.

With the default setting, the digital output is set to [adat]. You can select “adat” or “SP DIF”.

To output adat digital signals to a connected adat device, select “adat.” To output S/P DIF signals to a connected CD-R, MD, or DAT recorder, select “SP DIF.”

*See page “118” for more information on the [D. out?] menu.

When you finish setting the parameters in Setup mode, press the [EXIT/NO] key or the [STOP] button to exit Setup mode.

Connecting a Digital Mixer

The following explanations assume that this is digital mixer, which can input digital signals whose clock source can be setup at digital in.

ANALOGNALOGINPUTINPUTBALANCEB LANCE[ +4dBu[ +4dBu] / UNBALANCE] / UNB LANCE[ -10dBV[-10dBv] ]

 

4

3

2

1

8

7

6

5

 

 

 

 

ANALOGANALOGOUTPUTOUTPUTBALANCEBALANCE[ +4dBu[ +4dBu] / ]UNBALANCE/ UNBALANCE[ -10dBv[-10dBV] ]

 

 

 

 

 

 

 

12

11

10

9

8

7

6

5

4

3

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REMOTERS422

 

 

 

 

 

 

 

 

 

 

 

 

REMOTE

100Ω

THRU

 

 

 

 

 

 

 

 

 

 

 

 

ON OFF

 

24

23

22

21

20

19

18

17

16

15

14

13

 

 

WORDWORD

 

 

 

 

 

 

INPUT

OUTPUT

 

 

 

 

 

 

75Ω

 

 

 

 

 

 

 

ON

OFF

 

 

 

 

 

DATA

 

 

 

MIDIMIDI

SCSISCSI

 

INPUT

 

 

OUTPUT

 

INPUT

OUTPUT

THRU

24 - 17

16 - 9

8 - 1

24 - 17

16 - 9

8 - 1

CAUTION

AVIS: RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR

WARNING:

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.

AC-IN

Digital Out

Digital In

Word In

Digital Mixer

<Precaution against the digital loop>

When interconnecting D2424 and a digital mixer as shown in above schematic, if the D2424 “Setup of the digital input” is set to adat or “Sync” (synchronous mode) of S/P DIF, and the digital mixer clock source is set to “DIGITAL IN,” a digital loop will be created and it will not operate correctly.

In such a case, setup the D2424 “Setup of the digital input” to adat or “Async” (asynchronous mode) of S/P DIF.