FastIron GS Compact Layer 2 Switch Hardware Installation Guide

NOTE: This function takes advantage of information stored and supplied by the XFP device. This information is an optional feature of the Multi-Source Agreement standard defining the XFP interface. Not all component suppliers have implemented this feature set. In such cases where the XFP device does not supply the information, a “Not Available” message will be displayed for the specific port that the device is installed

Supported Media

The following media are currently available and supported by FastIron GD and LS devices:

CWDM80

CWDM100

LHA

LHB

1GE BXD

1GE BXU

100Mpbs BXD

100Mpbs BXU

SX2

100FX

100FX-1R

100FX-LR

OC12-MM

CLI Commands

The show media command displays module information including link length, vendor name, vendor part number, vendor revision, and laser wavelength.

[no] optical-monitor <alarm interval>

Use this command to configure monitoring for all ports (system-wide), a range or ports, or a single port. The <alarm-interval> variable sets the interval in minutes between the sending of alarms and messages. The default interval is three minutes. When monitoring is enabled, console messages, syslog messages, and SNMP traps are sent when warranted by optical operating conditions, and a port is enabled.

show optic port/slot_number

This command displays optical monitoring information as a result of the optical-monitorconfiguration command. Information includes:

temperature

TX power

RX power

TX bias current Status values are:

low-alarm

low-warn

normal

high-warn

high-alarm

7 - 18

© 2007 Foundry Networks, Inc.

September 2007

Page 86
Image 86