www.gateway.comAutoloader power specifications

Temperature Variation

Operating

50ºF (10ºC) per hour

Nonoperating

68ºF (20ºC) per hour

Humidity

 

 

 

Operating

20% to 80% noncondensing

 

 

Nonoperating

10% to 90% noncondensing

 

 

Gradient

10% per hour without condensation

 

 

Wet Bulb

 

 

 

Operating

78.8ºF (26ºC) max

Nonoperating

84.2ºF (29ºC) max

Altitude

 

 

 

Operating

-502 ft. to 10,000 ft. (-153 m to 3048 m)

 

 

Nonoperating

-502 ft. to 40,000 ft. (-153 m to 12192 m)

 

 

Autoloader power specifications

Line voltage

All Drive Types

 

60 Hz system: 90–265 VAC;

 

50 Hz system: 90–265 VAC

 

 

Maximum power

All Drive Types

 

160 W

 

 

Line frequency

All Drive Types

 

47–63 Hz

 

 

AC Input current

All Drive Types

 

60 Hz system: 4.0 A (RMS) for 115 VAC

 

50 Hz system: 2.0 A (RMS) for 230 VAC

 

 

Power consumption

All Drive Types

 

60 Hz = 75 W; 50 Hz = 80 W

 

 