www.gateway.com

Running diagnostic tests from the front panel

Front panel diagnostic tests

You can perform the following diagnostic tests using the front panel:

Halt Test

Loader—Self Test

Loader—Health Check

Loader—Picker Test

Loader—Magazine Test

Loader—Inventory Test

To perform any of the front panel diagnostic tests:

1From the Main menu, scroll to Diagnostics, then press ENTER. The Diagnostics submenu opens.

2Scroll to the test that you want to run, then press ENTER. If you are already logged in as Administrator, the test begins executing immediately.

- OR -

If you are not logged in, you are asked to enter the Administrator password. Do the following:

aFrom the front panel, enter the administrator password by using the up and down arrows to select each digit, then press ENTER to move to the next digit. To move to the previous digit, press ESC.

bWhen you have entered the entire six-digit password, you are asked to press ENTER one more time to submit the password. If the password is incorrect, you are asked to re-enter it using the same procedure. Otherwise, you are returned to the Diagnostics submenu. Press ENTER to run the desired test.

3The message “Running Test” appears while the test is running. To stop the test, see “Stopping a diagnostic test” on page 68.

The “Loader—Health Check” test displays an ongoing progress indicator while executing. When the test is finished, either the message “Test Successful” appears or the message “Test Failed” and an error code appear.

4If the test is successful, press ENTER to return to the Diagnostics test menu. For detailed results of a test, use On-board Remote Management to retrieve the diagnostic test status (see “Diagnostics using On-board Remote Management” on page 70).

- OR -

If the test is not successful, use the error code to evaluate the problem. (See the table of error codes on page 72.)

69