www.gateway.com

Error codes

 

 

The logs contain three main fields.

 

 

 

 

Field

Description

 

 

 

 

Time Stamp

The time the event occurred. This field helps correlate the event with a possible

 

 

application interruption. If the autoloader is unable to acquire the correct time/date

 

 

from the Simple Network Time Protocol (SNTP) server, or the front panel, the time

 

 

stamp contains values indicating the power cycle number and the time an entry

 

 

was written relative to that power cycle, listed as power on hours (POH).

 

 

The autoloader has no internal real-time clock and requires the user to set the time

 

 

of day from the front panel or acquire time through the network interface through

 

 

an SNTP server.

 

 

 

 

Error Code

The type of error or action to which the event is related. This field helps identify

 

 

what caused the event to occur (see “Error codes” on page 89).

 

 

 

 

Context

The event’s software register information.

 

 

 

Error codes

Error codes appear as eight-character strings made up of either letters or numbers for a total of 32 bits.

Field

Description

 

 

Recovery Action

Defines what the autoloader does, based on the event that occurred.

 

If the value is 0, the autoloader continues operations because this is typically a soft,

 

recoverable event, or an event that is just recording an action for when the development

 

team may be working on enhancements.

 

If the value is other than 0, then you must reboot the autoloader in order to recover from

 

the event. The reboot happens automatically.

 

Task ID: Defines what firmware task was being performed at the time of the event.

 

 

Task ID (in Hex)

Description

 

 

00

System Timer

 

 

01

Loader Manager

 

 

02

Picker

 

 

03

Magazine Left

 

 

04

Magazine Right

 

 

07

Drive Manager

 

 

08

Barcode Reader

 

 

09

Front Panel

 

 

0A

IP

 

 

0B

Diagnostic

 

 