www.gateway.com
Choosing a location
Preparation
Choose a location that meets the following criteria. The autoloader uses standard rack mounting hardware and must be flat and level.
Criteria | Description |
|
|
Rack requirements | Standard |
|
|
Room temperature | |
|
|
Power source | AC power voltage: |
| Line frequency: |
| Locate the AC outlet near the autoloader. The AC power cable is the product’s |
| main disconnect device and must be easily accessible at all times. |
|
|
Weight | 31 lb. (14.1 kg) unloaded |
| 38 lb. (17.2 kg) loaded with 2 magazines, 16 cartridges |
|
|
Air Quality | Minimize sources of particulate contamination. Avoid areas near frequently |
| used doors and walkways, cooling or exhaust vents, stacks of supplies that |
| collect dust, printers, and |
| Excessive dust and debris can damage tapes and tape drives. |
|
|
Humidity | |
|
|
Clearance | Back: Minimum of 17 inches (43.2 cm) |
| Front: Minimum of 27 inches (68.6 cm) |
| Sides: Minimum of 2 inches (5.08 cm) |
|
|
UL requirements
Elevated operating ambient temperature
When installed in a closed
Reduced air flow
When you install the autoloader in a rack, make sure that there is adequate air flow for safe operation.
Mechanical loading
When you install the autoloader in a rack, make sure that you do not load the rack unevenly (for example, all of the equipment in the top section of the rack).
11