www.gateway.com

Checking for errors

These errors appear on the LCD screen.

 

 

 

 

 

Field

Description

 

 

 

 

Time Stamp

The time the event occurred. This field helps

 

 

correlate the event with a possible

 

 

application interruption. If the autoloader is

 

 

unable to acquire the correct time/date from

 

 

the SNTP time server, or the front panel, the

 

 

time stamp contains values indicating the

 

 

power cycle number and the time an entry

 

 

was written relative to that power cycle,

 

 

listed as Power On Hours (POH).

 

 

The autoloader has no internal real-time

 

 

clock and requires the user to set the time of

 

 

day from the front panel or the network

 

 

interface (SNTP).

 

 

 

 

Error Code

The type of error and action to which the

 

 

event is related. This field helps identify what

 

 

caused the event to occur.

 

 

 

 

Context

The event’s software register information.

 

 

 

Error code field description

Error codes appear as 8-character strings made up of either letters or numbers for a total of 32 bits. The following table shows the block descriptor for the Hard Error log codes.

Bit

Description

 

 

0–3

Error Location

 

 

4–7

Error Location

 

 

8–11

Error Location

 

 

12–15

Error Location

 

 

16–19

Error Type

 

 

20–23

Error Type

 

 

24–27

Task ID

 

 

28–29

Task ID

 

 

30–31

Recovery Action

 

 