3–27

L2002 Inverter

 

“A” Function

Run

 

Defaults

 

 

 

 

Mode

 

 

 

Func.

Name /

 

–FE(F)

–FU

 

Description

Edit

Units

Code

SRW Display

Lo Hi

(EU)

(USA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A095

Acc1 to Acc2 frequency

Output frequency at which

✘ ✘

0.0

0.0

Hz

 

transition point

Accel1 switches to Accel2,

 

 

 

 

 

 

range is 0.0 to 400.0 Hz

 

 

 

 

 

ACC CHfr0000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A295

Acc1 to Acc2 frequency

Output frequency at which

✘ ✘

0.0

0.0

Hz

 

transition point, 2nd

Accel1 switches to Accel2,

 

 

 

 

 

motor

range is 0.0 to 400.0 Hz

 

 

 

 

 

 

 

 

 

 

 

 

2ACCCHfr0000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

A096

Dec1 to Dec2 frequency

Output frequency at which

✘ ✘

0.0

0.0

Hz

 

transition point

Decel1 switches to Decel2,

 

 

 

 

 

 

range is 0.0 to 400.0 Hz

 

 

 

 

 

DEC CHfr0000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A296

Dec1 to Dec2 frequency

Output frequency at which

✘ ✘

0.0

0.0

Hz

 

transition point, 2nd

Decel1 switches to Decel2,

 

 

 

 

 

motor

range is 0.0 to 400.0 Hz

 

 

 

 

 

 

 

 

 

 

 

 

2DECCHfr0000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: For A095 and A096 (and for 2nd motor settings), if you set a very rapid Acc1 or Dec1 time (less than 1.0 second), the inverter may not be able to change rates to Acc2 or Dec2 before reaching the target frequency. In that case, the inverter decreases the rate of Acc1 or Dec1 in order to achieve the second ramp to the target frequency.

Parameters Drive

Configuring