3–40

“B” Group: Fine Tuning Functions

 

 

“B” Function

Run

 

Defaults

 

 

 

 

 

Mode

 

 

 

Func.

Name /

 

 

–FE(F)

–FU

 

 

Description

Edit

Units

Code

SRW Display

Lo Hi

(EU)

(USA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B031

Software lock mode

Prevents parameter changes, in

✘ ✔

01

01

 

selection

 

five options, option codes:

 

 

 

 

 

 

 

00... Low-level access, [SFT]

 

 

 

 

 

S-Lock

MD1

 

 

 

 

 

input blocks all edits

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01... Low-level access, [SFT]

 

 

 

 

 

 

 

input blocks edits (except F001

 

 

 

 

 

 

 

and Multi-speed parameters)

 

 

 

 

 

 

 

02... No access to edits

 

 

 

 

 

 

 

03... No access to edits except

 

 

 

 

 

 

 

F001 and Multi-speed parame-

 

 

 

 

 

 

 

ters

 

 

 

 

 

 

 

10... High-level access, includ-

 

 

 

 

 

 

 

ing B031

 

 

 

 

 

 

 

 

 

 

 

 

Configuring

Drive Parameters

 

 

NOTE: To disable parameter editing when using B031 lock modes 00 and 01, assign the [SFT] function to one of the intelligent input terminals.

See “Software Lock” on page 4–22.