L2002 Inverter

3–53

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Function Summary Table

 

 

 

 

 

 

 

 

 

 

Option

Terminal

Function Name

 

Description

 

 

Code

Symbol

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

53

S-ST

Special-Set (select)

ON

The inverter uses 2nd motor parameters for

 

 

 

 

2nd Motor Data

 

generating frequency output to motor. The selec-

 

 

 

 

 

 

tion of 1st or 2nd motor is available during Stop

 

 

 

 

 

 

Mode or Run Mode.

 

 

 

 

 

 

 

 

 

 

 

 

OFF

The inverter uses 1st (main) motor parameters

 

 

 

 

 

 

for generating frequency output to motor

 

 

 

 

 

 

 

 

 

255

Not selected

ON

(input ignored)

 

 

 

 

 

 

 

 

 

 

 

 

OFF

(input ignored)

 

 

 

 

 

 

 

 

 

Note 1: When using the Multi-speed Select settings CF1 to CF4, do not display parameter F001 or change the value of F001 while the inverter is in Run Mode (motor running). If it is necessary to check the value of F001 during Run Mode, please monitor D001 instead of F001.

Parameters Drive

Configuring