4–59

L2002 Inverter

Having two motor profiles lets you store two “personalities” for motors in one inverter’s memory. The inverter allows the final selection between the two motor types to be made in the field through the use of an intelligent input terminal function [SET]. This provides an extra level of flexibility needed in particular situations. See the following table.

Parameters for the second motor have a function code of the form x2xx. They appear immediately after the first motor’s parameter in the menu listing order. The following table lists the parameters that have the second parameter register for programming.

Function Name

Parameter Codes

 

 

 

 

 

 

1st motor2nd motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multi-speed frequency setting

A020

A220

 

 

 

 

 

 

 

Acceleration (1) time setting

F002

F202

 

 

 

 

 

 

 

Deceleration (1) time setting

F003

F203

 

 

 

 

 

 

 

Acceleration (2) time setting

A092

A292

 

 

 

 

 

 

 

Deceleration (2) time setting

A093

A293

 

 

 

 

 

 

 

Select method to use Acc2/Dec2

A094

A294

 

 

 

 

 

 

 

Acc1 to Acc2 frequency transition point

A095

A295

 

 

 

 

 

 

 

Dec1 to Dec2 frequency transition point

A096

A296

 

 

 

 

 

 

 

Level of electronic thermal setting

B012

B212

 

 

 

 

 

 

 

Electronic thermal characteristic

B013

B213

 

 

 

 

 

 

 

Torque boost select

A041

A241

 

 

 

 

 

 

 

Manual torque boost value

A042

A242

 

 

 

 

 

 

 

Manual torque boost frequency adjustment

A043

A243

 

 

 

 

 

 

 

V/f characteristic curve selection

A044

A244

 

 

 

 

 

 

 

 

iSLV voltage gain

A046

A246

 

Operations Monitoringand

 

 

 

 

iSLV slip compensation

A047

A247

 

 

 

 

 

Frequency lower limit setting

A062

A262

 

Base frequency setting

A003

A203

 

 

Maximum frequency setting

A004

A204

 

 

Frequency upper limit setting

A061

A261

 

 

 

 

 

 

 

 

 

 

 

 

Motor capacity

H003

H203

 

 

 

 

 

 

 

Motor poles setting

H004

H204

 

 

 

 

 

 

 

Motor stabilization constant

H006

H206