A005

[AT] selection

Four options, select codes:

✘ ✔

00

00

Hz

 

 

 

 

 

00 .. Select between [O] and

 

 

 

 

 

 

 

AT-Slct

O/OI

 

 

 

 

 

 

 

[OI] at [AT]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01 .. [O] + [OI] ([AT] input is

 

 

 

 

 

 

 

 

 

ignored)

 

 

 

 

 

 

 

 

 

02 .. Select between [O] and

 

 

 

 

 

 

 

 

 

keypad potentiometer

 

 

 

 

 

 

 

 

 

03 .. Select between [OI] and

 

 

 

 

 

 

 

 

 

keypad potentiometer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A011

O–L input active range

The output frequency corre-

✘ ✔

0.0

0.0

Hz

 

 

 

start frequency

sponding to the analog input

 

 

 

 

 

 

 

 

 

range starting point,

 

 

 

 

 

 

 

O-EXS

0000.0Hz

 

 

 

 

 

 

 

range is 0.0 to 400.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A012

O–L input active range

The output frequency corre-

✘ ✔

0.0

0.0

Hz

 

 

 

end frequency

sponding to the analog input

 

 

 

 

 

 

 

 

 

range ending point,

 

 

 

 

 

 

 

O-EXE

0000.0Hz

 

 

 

 

 

 

 

range is 0.0 to 400.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A013

O–L input active range

The starting point (offset) for

✘ ✔

0.

0.

%

 

Configuring ParametersDrive

 

start voltage

the active analog input range,

 

 

 

 

 

 

 

 

range is 0. to 100.

 

 

 

 

 

 

O-EX%S

00000%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A014

O–L input active range

The ending point (offset) for

✘ ✔

100.

100.

%

 

 

 

end voltage

the active analog input range,

 

 

 

 

 

 

 

 

 

range is 0. to 100.

 

 

 

 

 

 

 

O-EX%E

00100%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A015

O–L input start

Two options; select codes:

✘ ✔

01

01

 

 

 

frequency enable

00 .. Use offset (A011 value)

 

 

 

 

 

 

 

 

 

01 .. Use 0 Hz

 

 

 

 

 

 

 

O-LVL

0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A016

External frequency

One range plus one setting:

✘ ✔

2.

8.

Sam-

 

 

 

filter time constant

01 to 16... Moving average,

 

 

 

ples

 

 

 

 

 

where n=1 to 16 (number of

 

 

 

 

 

 

 

F-SAMP

00008

 

 

 

 

 

 

 

samples for average)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17 .. Use 16-sample average,

 

 

 

 

 

 

 

 

 

plus deadband +0.1/–0.2Hz.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A016: External Frequency Filter Time Constant – This filter smooths the analog input signal

 

for the inverter’s output frequency reference.

A016 sets the filter range n=1 to 16. This is a simple moving average calculation, where n (number of samples) is variable.

A016 = 17 is a special value. It configures the inverter to use a moveable deadband feature. Initially the inverter uses the average of the previous 16 samples. Then, the deadband is employed for each subsequent average of 16 samples. The deadband works by ignoring small fluctuations in each new average: less than +0.1Hz or –0.2Hz change. When a 16-sample average exceeds this deadband, then the inverter applies that average to the output frequency reference, and it also becomes the new deadband comparison point for subsequent sample averages.