3–36

“B” Group: Fine Tuning Functions

Configuring

Drive Parameters

 

 

Note 1: For inverter models 005NFE(F), 011NFE(F), and 030HFE(F), the overload- related parameter settings are different from the rated amperes. Therefore, be sure to set the electronic thermal overload according to the actual motor driven by the particular inverter.

Inverter Model

B012/B212

B022

C041

Inverter rated

(A)

(A)

(A)

Amperes (A)

 

 

 

 

 

 

 

 

 

 

 

–004NFE(F)

2.60

3.90

2.60

2.60

 

 

 

 

 

–005NFE(F)

4.00

6.00

4.00

3.00

 

 

 

 

 

–007NFE(F)

4.00

6.00

4.00

4.00

 

 

 

 

 

–0011NFE(F)

7.10

10.65

7.10

5.00

 

 

 

 

 

–015NFE(F)

7.10

10.65

7.10

7.10

 

 

 

 

 

–030NFE(F)

8.60

12.90

8.60

7.80

 

 

 

 

 

–040NFE(F)

8.60

12.90

8.60

8.60

 

 

 

 

 

WARNING: When parameter B012, level of electronic thermal setting, is set to motor FLA rating (Full Load Ampere nameplate rating), the inverter provides solid state motor overload protection at 115% of motor FLA or equivalent. If parameter B012 exceeds the motor FLA rating, the motor may overheat and be damaged. Parameter B012, level of electronic thermal setting, is a variable parameter.