L2002 Inverter

 

B–33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Holding Registers for “A” Group Standard Functions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Network Data

 

 

 

Func.

 

 

 

 

 

 

 

 

 

Name

R/W

Description

Register

 

 

 

 

Code

Range

 

Res.

 

 

 

 

 

 

 

 

 

 

 

 

hex

dec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A152

Pot. input active range

R/W

The output frequency corre-

1097h

4247

0 to 4000

 

0.1 Hz

 

 

end frequency

 

sponding to the potentiometer

 

 

 

 

 

 

 

 

 

range ending point,

 

 

 

 

 

 

 

 

 

range is 0.0 to 400.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A153

Pot. input active range

R/W

The output frequency corre-

1098h

4248

0 to 100

 

1%

 

 

start current

 

sponding to the potentiometer

 

 

 

 

 

 

 

 

 

range starting point,

 

 

 

 

 

Appendix

 

 

 

range is 0 to 100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A154

Pot. input active range

R/W

The output frequency corre-

1099h

4249

0 to 100

 

1%

 

 

end current

 

sponding to the potentiometer

 

 

 

 

 

 

 

 

 

range ending point,

 

 

 

 

 

B

 

 

 

range is 0 to 100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A155

Pot. input start

R/W

Two options:

109Ah

4250

0, 1

 

 

 

frequency enable

 

00... Disable

 

 

 

 

 

 

 

 

 

01... Enable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 