3–48

“C” Group: Intelligent Terminal Functions

Configuring

Drive Parameters

 

 

 

 

“C” Function

Run

 

Defaults

 

 

 

 

 

Mode

 

 

 

Func.

Name /

 

–FE(F)

–FU

 

Description

Edit

Units

Code

SRW Display

Lo Hi

(EU)

(USA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C004

Terminal [4] function

Select terminal [4] function,

✘ ✘

03

13

 

 

 

29 options (see next section)

 

[CF2]

[USP]

 

 

IN-TM 4

USP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C204

Terminal [4] function,

Select terminal [4] function,

✘ ✘

03

13

 

2nd motor

 

29 options (see next section)

 

[CF2]

[USP]

 

 

 

 

 

 

 

 

 

 

2IN-TM 4

USP

 

 

 

 

 

 

 

 

 

 

 

 

C005

Terminal [5] function

Select terminal [5] function,

✘ ✘

18

09

 

 

 

30 options (see next section)

 

[RS]

[2CH]

 

 

IN-TM 5

2CH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C205

Terminal [5] function,

Select terminal [5] function,

✘ ✘

18

09

 

2nd motor

 

30 options (see next section)

 

[RS]

[2CH]

 

 

 

 

 

 

 

 

 

 

2IN-TM 5

2CH

 

 

 

 

 

 

 

 

 

 

 

 

 

The input logic convention is programmable for each of the five inputs. Most inputs default to normally open (active high), but you can select normally closed (active low) in order to invert the sense of the logic.

 

 

“C” Function

Run

 

Defaults

 

 

 

 

 

Mode

 

 

 

Func.

 

Name /

 

–FE(F)

–FU

 

 

Description

Edit

Units

Code

SRW Display

Lo Hi

(EU)

(USA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C011

Terminal [1] active state

Select logic convention, two

✘ ✘

00

00

 

 

 

option codes:

 

 

 

 

 

O/C-1

NO

 

 

 

 

 

00... normally open [NO]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01... normally closed [NC]

 

 

 

 

 

 

 

 

 

 

 

C012

Terminal [2] active state

Select logic convention, two

✘ ✘

00

00

 

 

 

option codes:

 

 

 

 

 

O/C-2

NO

 

 

 

 

 

00... normally open [NO]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01... normally closed [NC]

 

 

 

 

 

 

 

 

 

 

 

C013

Terminal [3] active state

Select logic convention, two

✘ ✘

00

00

 

 

 

option codes:

 

 

 

 

 

O/C-3

NO

 

 

 

 

 

00... normally open [NO]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01... normally closed [NC]

 

 

 

 

 

 

 

 

 

 

 

C014

Terminal [4] active state

Select logic convention, two

✘ ✘

00

01

 

 

 

option codes:

 

 

 

 

 

O/C-4

NC

 

 

 

 

 

00... normally open [NO]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01... normally closed [NC]

 

 

 

 

 

 

 

 

 

 

 

C015

Terminal [5] active state

Select logic convention, two

✘ ✘

00

00

 

 

 

option codes:

 

 

 

 

 

O/C-5

NO

 

 

 

 

 

00... normally open [NO]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01... normally closed [NC]