Switch Manager

the broadcast is in a hard zone, the frame is retransmitted on all online F_Ports within the hard zone. If the originator of the broadcast frame is not in a hard zone, the frame is retransmitted on online F_Ports that are not in a hard zone. The default setting is disabled.

In-band Management parameter

In-band Management is the ability to manage switches across inter-switch links using Switch Manager, SNMP, management server. The switch comes from the factory with in-band management enabled. If you disable in-band management on a particular switch, you can no longer communicate with that switch by means other than a direct Ethernet or serial connection. In-band Management is not supported at this time.

Interop Mode parameter

When a zone set is activated, this and other FC-SW-2 compliant switches propagate the active zone set to all switches in the fabric. Some non-FC-SW-2 compliant switches propagate not only the active zone set, but the entire zoning database. Disabling the Interop Mode parameter causes the Switch switch to propagate the zoning database, and therefore, interoperate with non-FC-SW-2 switches. For FC-SW-2 compliant fabrics, the Interop Mode parameter should be enabled. Interop Mode is not supported at this time.

Legacy Address Format parameter

Legacy Address Format should be enabled only to permit interoperation with certain older non-FC-SW-2 switches. Enabling this setting under other circumstances disables zoning that is defined by domain ID and port number. This setting is available only when the Interop Mode setting is disabled. Contact your HP authorized service provider for assistance in using this feature. Legacy Address Format is not supported at this time.

Timeout Values parameters

The switch timeout values determine the timeout values for all ports on the switch. Table 14 describes the switch timeout parameters. The timeout values must be the same for all switches in the fabric.

Note: Mismatched timeout values disrupt the fabric. These values should not be changed unless absolutely necessary. The switch must be offline to change the values. Use the Switch Properties dialog box to take the switch offline.

Table 14: Timeout values

 

 

 

 

Parameter

 

Description

R_A_TOV

 

Resource Allocation Timeout: Represents the maximum time a frame

 

 

could be delayed in the fabric and still be delivered. The default is

 

 

10000 milliseconds.

 

 

 

E_D_TOV

 

Error Detect Timeout: Represents the maximum round trip time that an

 

 

operation between two N_Ports could require. The default is 2000

 

 

milliseconds.