Command Line Interface

Table 57: Show Port parameters (Continued)

Entry

Description

Link Failures

Number of optical link failures detected by this port. A link

 

failure is a loss of synchronization or a loss of signal while not

 

in the offline state. A loss of signal causes the switch to

 

attempt to re-establish the link. If the link is not re-established,

 

a link failure is counted. A link reset is performed after a link

 

failure.

 

 

Login

Number of device logins

 

 

Logout

Number of device logouts

 

 

LoopTimeouts

A two (2) second timeout as specified by FC-AL-2.

 

 

LossOfSync

Number of synchronization losses (>100 ms) detected by this

 

port. A loss of synchronization is detected by receipt of an

 

invalid transmission word.

 

 

PrimSeqErrors

Primitive sequence errors detected.

 

 

RxLinkResets

Number of link reset primitives received from an attached

 

device.

 

 

RxOfflineSeq

Number of offline sequences received. An OLS is issued for

 

link initialization, a Receive & Recognize Not_Operational

 

(NOS) state, or to enter the offline state.

 

 

TotalErrors

Total number of errors detected.

 

 

TotalLIPsRecvd

Number of loop initialization primitive frames received by this

 

port.

 

 

TotalLIPsXmitd

Number of loop initialization primitive frames transmitted by

 

this port.

 

 

TotalLinkResets

Total number of link reset primitives.

 

 

TotalOfflineSeq

Total number of Offline Sequences issued and received by this

 

port.

 

 

TotalRxFrames

Total number of frames received by this port.

 

 

TotalRxWords

Total number of words received by this port.

 

 

TotalTxFrames

Total number of frames issued by this port.

 

 

TotalTxWords

Total number of words issued by this port.

 

 

TxLinkResets

Number of Link Resets issued by this port.

 

 

TxOfflineSeq

Total number of Offline Sequences issued by this port.

 

 

post log

Displays the Power On Self Test (POST) log which contains results from the POST.

setup [option]

Displays setup attributes for the system, SNMP, and the switch manufacturer. See the Show Setup command” on page 166.

steering [domain_id]

Displays the routes that data takes to the switch given by [domain_id]. If you omit [domain_id], the system displays routes for all switches in the fabric.